ArticleClinical orthopaedics and related research2019
Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?
Article in Clinical orthopaedics and related research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 11 citations in OpenAlex.
- Does the presence of a lipped highly crosslinked polyethylene liner affect the survival of total hip arthroplasty implants? : a registry-based retrospective cohort study.Bone & joint open · 2026Article
- [Standard and special liner in primary hip arthroplasty : Current study and survey results from the German Arthroplasty Registry (EPRD)].Orthopadie (Heidelberg, Germany) · 2023Review
- Article
- Using an asymmetric crosslinked polyethylene liner in primary total hip arthroplasty is associated with a lower risk of revision surgery : an analysis of the National Joint Registry.The bone & joint journal · 2021Article
- Article
- CORR Insights®: Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?Clinical orthopaedics and related research · 2019Article
Corrections and comments
- Commented on by
Authors and funding
4 authors at 1 institution in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHooded acetabular liners and head sizes ≥ 32 mm have both shown to have a beneficial effect on the revision rate for dislocation in THA. Experience with noncrosslinked polyethylene (nonXLPE) raised concerns regarding the risk of impingement damage, loosening, and osteolysis with hooded liners; however, the evidence for this in crosslinked polyethylene (XLPE) is inconclusive. The interaction between different femoral head sizes and hooded liners is not well understood, and it is unclear whether hooded XLPE liners have a beneficial effect on overall long-term survivorship. QUESTIONS/PURPOSES: We analyzed a large national joint registry to ask: (1) Is the use of hooded XLPE liners associated with a reduced revision rate for dislocation compared with nonhooded liners? (2) Is there a difference in the revision rate for aseptic loosening/osteolysis? (3) Is head size associated with any difference in the revision rate between hooded and nonhooded liners?
methodsThe Australian Orthopaedic Association National Joint Replacement Registry longitudinally maintains data on all primary and revision joint arthroplasties with nearly 100% capture. We analyzed all conventional primary THAs performed from registry inception in September 1999 until December 31, 2016 in patients with a diagnosis of osteoarthritis who had nonhooded or hooded XLPE bearings in a cementless acetabular shell. The study group included 192,659 THA procedures with XLPE liners, of which 67,904 were nonhooded and 124,755 were hooded. The mean age of patients receiving nonhooded liners was 70 years (range, 11-100 years); 44% were males. This was similar to the patients with hooded liners, who had a mean age of 70 years (range, 16-100 years); 45% were males. The main outcome measure was the cumulative percent revision at 15 years of the THA using Kaplan-Meier estimates of survivorship. We examined reasons for revision and and performed multivariable analysis to control for the confounding factors of three head size groups (< 32mm, 32mm, and > 32mm) and for the method of femoral fixation.
resultsThere was a higher revision rate for dislocation for patients with nonhooded liners at all times to 15 years (HR, 1.31; 95% CI, 1.17-1.47; p < 0.001). There was a higher revision rate for the diagnosis of aseptic loosening/osteolysis with patients with nonhooded liners compared with hooded liners (HR, 1.19; 95% CI, 1.05-1.34; p = 0.006). Head sizes of 32 mm or larger were independently associated with a lower comparative revision rate between hooded and nonhooded liners, but this was not apparent for head sizes smaller than 32 mm. It appeared that the main driver of the finding in larger heads was a reduced dislocation risk with hooded liners for 32 mm heads (HR, 1.50; 95% CI, 1.23-1.80; p < 0.001) and for heads larger than 32 mm (HR, 1.50; 95% CI, 1.20-1.89; p < 0.001).
conclusionsPrior research has suggested that hooded acetabular liners may be associated with impingement, loosening, and osteolysis; however, in this large, registry-based report we found that XLPE hooded liners are not associated with an increased revision rate for aseptic loosening/osteolysis. Although there are many potential confounding variables in this registry analysis, if anything, surgeons using larger femoral heads and hooded liners likely did so in patients with a higher perceived dislocation risk. Patients with larger heads and XLPE hooded liners were, however, less likely to experience revision for dislocation. These liners therefore appear reasonable to use in primary THA at the surgeon's discretion. LEVEL OF EVIDENCE: Level III, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.