Effect of changes in monitor unit rate and energy on dose rate of total marrow irradiation based on Linac volumetric arc therapy.

Jaeman Son, Noorie Choi, Jung-In Kim, Jong Min Park, Hong-Gyun Wu, Hyun-Cheol Kang, Chang Heon Choi

Abstract readEvaluation Study
In one paragraph

Article in Radiation oncology (London, England), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jaeman SonDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Noorie ChoiDepartment of Radiation Oncology, Veterans Health Service Medical Center, Seoul, South Korea.ORCID http://orcid.org/0000-0003-0449-1372
Jung-In KimDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Jong Min ParkDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Hong-Gyun WuDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Hyun-Cheol KangDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. shule@snu.ac.kr.
Chang Heon ChoiDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. dm140@naver.com.

Funding

National R&D Program for Cancer Control HA 16C0025National Research Foundation of Korea 2017M2A2A7A02020641
6 · The paper itself

Abstract

backgroundThis study set out to evaluate the effect of dose rate on normal tissues (the lung, in particular) and the variation in the treatment efficiency as determined by the monitor unit (MU) and energy applied in Linac-based volumetric arc therapy (VMAT) total marrow irradiation (TMI).

methodsLinac-based VMAT plans were generated for the TMI for six patients. The planning target volume (PTV) was divided into six sub-volumes, each of which had their own isocenter. To examine the effect of the dose rate and energy, a range of MU rates (40, 60, 80, 100, 300, and 600 MU/min) were selected for 6, 10, and 15 MV. All the plans were verified by portal dosimetry.

resultsThe dosimetric parameters for the target and normal tissue were consistent in terms of the energy and MU rate. The beam-on time was changed from 59.6 to 6 min for 40 and 600 MU/min. When 40 MU/min was set for the lung, the dose rate delivered to the lung was less than 6 cGy/min (that is, 90%), while the beam-on time was approximately 10 min. The percentage volume of the lung receiving 20 cGy/min was 1.47, 3.94, and 6.22% at 6, 10, and 15 MV, respectively. However, for 600 MU/min, the total lung volume received over 6 cGy/min regardless of the energy, and over 20 cGy/min for 10 and 15 MV (i.e., 54.4% for 6 MV).

conclusionsIn TMI treatment, reducing the dose rate administered to the lung can decrease the incidence of pulmonary toxicity. To reduce the probability of normal tissue complications, the selection of the lowest MU rate is recommended for fields including the lung. To minimize the total treatment time, the maximum MU rate can be applied to other fields.

Indexed as

Bone MarrowDose-Response Relationship, RadiationFemaleHumansLungLung InjuryMaleOrgans at RiskRadiometryRadiosurgeryRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedWhole-Body IrradiationDose rateMonitor unit ratePulmonary toxicityTotal marrow irradiationVolumetric arc therapy

Identifiers

PMID31133030
PMCPMC6537431

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.