Evidence map›Paper›PMID 31131509›Full record

ArticleJournal of clinical laboratory analysis2019

Performance evaluation of serum PIVKA-II measurement using HISCL-5000 and a method comparison of HISCL-5000, LUMIPULSE G1200, and ARCHITECT i2000.

Mi Ra Ryu, Eun-Suk Kang, Hyung-Doo Park

Open access · goldAbstract readComparative StudyEvaluation Study
In one paragraph

Article in Journal of clinical laboratory analysis, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 14 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Tumor biomarkers for diagnosis, prognosis and targeted therapy.Signal transduction and targeted therapy · 2024
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Mi Ra RyuDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Eun-Suk KangDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-6386-6520
Hyung-Doo ParkDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0003-1798-773X
Samsung Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProtein induced by vitamin K antagonist-II (PIVKA-II), in addition to alpha-fetoprotein, is a useful tumor marker for diagnosis of hepatocellular carcinoma (HCC). We evaluated the analytical performance of the HISCL-5000 analyzer (Sysmex Corporation) in the measurement of serum PIVKA-II.

methodsWe evaluated the precision and linearity of PIVKA-II assays using the HISCL-5000 analyzer. Methods using HISCL-5000, LUMIPULSE G1200 (Fujirebio Diagnostics), and ARCHITECT i2000 (Abbott Diagnostics) were compared according to the guidelines of the Clinical and Laboratory Standards Institute. A total of 501 subjects (median age 59 years, age range 24-90 years) were enrolled. Among them, 335 were HCC patients, 46 were patients with non-HCC liver disease, and 120 were healthy individuals. Non-HCC liver disease included liver cirrhosis, chronic hepatitis, HBV or HCV carrier, hepatic adenoma, and intrahepatic cholangiocarcinoma.

resultsRepeatability (%CV) in low- and high-level controls and pooled serum was 2.81%-10.30%, and within-laboratory precision was 4.24%-8.86%. In a linearity test, the coefficient of determination (R

conclusionsA PIVKA-II assay using HISCL-5000 showed acceptable analytical performance including precision, linearity, and method comparison. This indicates that HISCL-5000 can be potentially helpful in clinical laboratories.

Indexed as

AdultAgedAged, 80 and overBiomarkersBlood Chemical AnalysisEnzyme-Linked Immunosorbent AssayFemaleHumansLiver DiseasesMaleMiddle AgedProtein PrecursorsProthrombinReproducibility of ResultsYoung AdultacarboxyprothrombinBiomarkersProtein PrecursorsProthrombinanalytical performanceARCHITECT i2000HISCL-5000LUMIPULSE G1200PIVKA-II

Identifiers

PMID31131509
PMCPMC6642327
OpenAlexW2946962665

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.