Evidence map›Paper›PMID 31131154›Full record

ArticleAmerican journal of cardiovascular disease2019

Health outcomes of on-pump pulmonary valve replacement surgery with and without cardioplegic arrest: a comparison study in tetralogy of Fallot subjects.

Goodarz Chehri, Jalal Moludi, Ali Sadeghpour Tabaei, Sepehr Sadeghpour Tabaei

Open access · greenAbstract read
In one paragraph

Article in American journal of cardiovascular disease, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 76% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Goodarz ChehriDepartment of Cardiac Surgery, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences Tehran, Iran.
Jalal MoludiNutrition Research Center, Faculty of Nutrition, Tabriz University of Medical Sciences Tabriz, Iran.
Ali Sadeghpour TabaeiDepartment of Cardiac Surgery, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences Tehran, Iran.
Sepehr Sadeghpour TabaeiSchool of Medicine, Shahid Beheshti University of Medical Sciences Tehran, Iran.
Shahid Beheshti University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTetralogy of Fallot is one of the most common congenital heart diseases in which four important cardiovascular defects. Pulmonary valve regurgitation (PVR) after TOF surgery is one of the indications for its replacement which is carried out with two surgical methods, on-pump surgery with and without cardiac arrest.

objectiveThe aim of this study was to compare the results of the pulmonary valve replacement surgery with and without cardiac arrest. MATERIALS AND

methodsIn this retrospective study, the information of medical records of all patients with TOF that candidates for pulmonary valve replacement from 2008 to 2014, whom treated in Kermanshah's Imam Ali cardiac hospital, Kermanshah. Iran and Shaheed Rajaei Heart Center in Tehran with the two common surgical procedure, with and without cardiac arrest, were studied. With matching for age and sex, 33 patients enrolled in this study, 16 patients underwent surgery with the arrest (in Kermanshah's Imam Ali cardiac hospital, Kermanshah. Iran) and 17 subjects operated without cardiac arrest (on pump beating heart in Shaheed Rajaei Heart Center in Tehran).

resultsThe results of this study showed that patients operated using without cardiac arrest compared to the with cardiac arrest, were superior in the hospital and ICU stay, bleeding until 24 hours after surgery, intubated time, inotropic support, and duration of surgery (P<0.05). Also, hemoglobin, blood pressure, ejection fraction (EF), and tricuspid regurgitation after surgery were statistically significant difference between two groups (P<0.05).

conclusionThe results of this study showed that although during the (on pump beating heart without aortic cross clamp) without cardiac arrest surgery method some problems may be created for the surgeon, nevertheless, patients after without arrested procedure have a better outcomes compared to the cardiac arrest method.

Indexed as

cardiopulmonary bypasscongenital heart diseasePulmonary valve regurgitationpulmonary valve replacementtetralogy of Fallot

Identifiers

PMID31131154
PMCPMC6526353
OpenAlexW3003586723

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.