Evidence map›Paper›PMID 31126346›Full record

ArticleJournal of orthopaedic surgery and research2019

The 10-year outcomes of the ASR XL Acetabular System: a single-center experience from China.

Guojun Jin, Jisheng Ran, Weiping Chen, Yan Xiong, Jiapeng Bao, Lidong Wu

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Guojun JinDepartment of Orthopedics, Taizhou First People's Hospital, 218th Hengjie Road, Taizhou, 318020, China.
Jisheng RanDepartment of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, 88th Jie Fang Road, Hangzhou, 310009, China.
Weiping ChenDepartment of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, 88th Jie Fang Road, Hangzhou, 310009, China.
Yan XiongDepartment of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, 88th Jie Fang Road, Hangzhou, 310009, China.
Jiapeng BaoDepartment of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, 88th Jie Fang Road, Hangzhou, 310009, China.
Lidong WuDepartment of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, 88th Jie Fang Road, Hangzhou, 310009, China. wulidong@zju.edu.cn.

Funding

Taizhou Municipal Science and Technology Bureau 15yw05
6 · The paper itself

Abstract

backgroundThe revision rate of articular surface replacement (ASR) implants continues to rise in China because of metal debris. However, there are few reports on the clinical results of ASR implants with prolonged follow-up time in China. This study investigated the clinical outcomes and the risk factors of revision surgery in patients with ASR implants.

methodsIn total, 74 patients (74 hips) who underwent primary total hip arthroplasty (THA) with ASR implants over the past 4 to 10 years were retrospectively analyzed. Relevant clinical, radiographic, and biochemical data were examined.

resultsThe average follow-up time was 88.46 (range 23-114) months, and the ASR implants of 18 hips (24.3%) were revised. Patients who received revision surgery had worse joint function with significantly lower Harris Hip Score and Western Ontario and McMaster Universities index than non-revision patients (61.11 ± 6.68 vs 85.30 ± 9.16, p < 0.001; 61.00 ± 3.83 vs 79.04 ± 14.49, p < 0.001; respectively). Higher acetabular abduction angle and serum Co and Cr concentration were significantly relevant to worse joint function as measured by HSS (p = 0.018, 0.009, 0.043, respectively). ROC curve analysis was applied to categorize the optimal cutoff values of acetabular abduction angle and serum Cr and Co concentration for revision surgery, which were settled as 47.80°, 98.44 μg/L, and 6.95 μg/L, respectively. Overall survival of the prostheses with high acetabular abduction angle (> 47.80°, HR = 70.145, 95% CI 1.558-3158.213, p = 0.029), high serum Cr concentration (98.44 μg/L, HR = 58.956, 95% CI 1.294-2685.203, p = 0.036), and high serum Co concentration (> 6.95 μg/L, HR = 179.511, 95% CI 2.360-13656.941, p = 0.019) decreased significantly than the lower groups.

conclusionsEvaluation of the DePuy ASR XL articulation demonstrated increased rates of revision following a longer follow-up period. High acetabular abduction angle and serum Cr and Co concentration correlated with worse clinical outcomes and high revision rate. Therefore, we advocate that patients with DePuy ASR XL implants be followed up more closely than those with other implants, especially with high acetabular abduction angle and serum Cr or Co concentration.

Indexed as

AcetabulumAdultAgedArthroplasty, Replacement, HipChinaFemaleFollow-Up StudiesHip ProsthesisHumansMaleMiddle AgedProspective StudiesTime FactorsTreatment OutcomeMetal ionMetal-on-metalSurvivorship analysisTotal hip arthroplasty

Identifiers

PMID31126346
PMCPMC6534829

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.