Evidence map›Paper›PMID 31125076›Full record

ArticleJournal of radiation research2019

Factual survey of the clinical use of deformable image registration software for radiotherapy in Japan.

Noriyuki Kadoya, Satoshi Kito, Masahiko Kurooka, Masahide Saito, Akihiro Takemura, Naoki Tohyama, Masahide Tominaga, Yujiro Nakajima, Yukio Fujita, Yuki Miyabe

Open access · goldAbstract read
In one paragraph

Article in Journal of radiation research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 8 institutions in 1 country.

Noriyuki KadoyaDepartment of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Satoshi KitoDepartment of Radiotherapy, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, Japan.
Masahiko KurookaDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.
Masahide SaitoDepartment of Radiology, University of Yamanashi, Yamanashi, Japan.
Akihiro TakemuraFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan.
Naoki TohyamaDepartment of Radiation Oncology, Tokyo Bay Advanced Imaging and Radiation Oncology Clinic Makuhari, Chiba, Japan.
Masahide TominagaDepartment of Therapeutic Radiology, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.
Yujiro NakajimaDepartment of Radiotherapy, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, Japan.
Yukio FujitaDepartment of Radiological Sciences, Faculty of Health Sciences, Komazawa University, Tokyo, Japan.
Yuki MiyabeDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Tokyo Metropolitan Komagome Hospital · JPKanazawa University · JPKomazawa University · JPKyoto University · JPTohoku University · JPTokushima University · JPTokyo Medical University · JPUniversity of Yamanashi · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Deformable image registration (DIR) has recently become commercially available in the field of radiotherapy. However, there was no detailed information regarding the use of DIR software at each medical institution. Thus, in this study, we surveyed the status of the clinical use of DIR software for radiotherapy in Japan. The Japan Society of Medical Physics and the Japanese Society for Radiation Oncology mailing lists were used to announce this survey. The questionnaire was created by investigators working under the research grant of the Japanese Society for Radiation Oncology (2017-2018) and intended for the collection of information regarding the use of DIR in radiotherapy. The survey was completed by 161 institutions in Japan. The survey results showed that dose accumulation was the most frequent purpose for which DIR was used in clinical practice (73%). Various commissioning methods were performed, although they were not standardized. Qualitative evaluation with actual patient images was the most commonly used method (28%), although 30% of the total number of responses (42% of institutions) reported that they do not perform commissioning. We surveyed the current status of clinical use of DIR software for radiotherapy in Japan for the first time. Our results indicated that a certain number of institutions used DIR software for clinical practice, and various commissioning methods were performed, although they were not standardized. Taken together, these findings highlight the need for a technically unified approach for commissioning and quality assurance for the use of DIR software in Japan.

Indexed as

Radiographic Image Interpretation, Computer-AssistedSoftwareAlgorithmsHumansJapanPhantoms, ImagingQuality Assurance, Health CareRadiation OncologyRadiotherapyRadiotherapy DosageRadiotherapy Planning, Computer-AssistedSurveys and QuestionnairesTreatment Outcomedeformable image registrationdose accumulationpropagationradiotherapysegmentation

Identifiers

PMID31125076
PMCPMC6640912
OpenAlexW2945745825

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked