ArticleSensors (Basel, Switzerland)2019
Sugar Concentration Measurement System Using Radiofrequency Sensor.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 7 citations in OpenAlex.
- Sugar Detection in Aqueous Solution Using an SMS Fiber Device.Sensors (Basel, Switzerland) · 2023Article
- Molecular Level Sucrose Quantification: A Critical Review.Sensors (Basel, Switzerland) · 2022Review
- mmW Rotman Lens-Based Sensing: An Investigation Study.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A sugar solution measurement system was developed based on the dielectric properties of the sucrose molecule. An ac conductivity and tan δ study as a function of the frequency was performed to find the suitable frequency range for the measuring system. The results indicate that it is possible to obtain a better response of the sensor using the frequencies as the maxima peak in tan δ appears. Developed setup for sucrose solution was appropriate to measure in a 0.15 to 1 g/mL range with an experimental error of about 3%. The proposed system improves the measurement time over some other methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.