Evidence map›Paper›PMID 31119745›Full record

ArticlePacing and clinical electrophysiology : PACE2019

Clinical evaluation of a small implantable cardiac monitor with a long sensing vector.

Christopher Piorkowski, Mathias Busch, Georg Nölker, Jörn Schmitt, Franz Xaver Roithinger, Glenn Young, Miloš Táborský, Gundula Herrmann, Dietmar Schmitz

Abstract readEvaluation StudyMulticenter Study
In one paragraph

Article in Pacing and clinical electrophysiology : PACE, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Observational
  9. Review
  10. Accuracy of atrial fibrillation detection by an insertable cardiac monitor in patients undergoing catheter ablation: Results of the BioVAD study.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2022
    Article
  11. Article
  12. Effectiveness of SharpSense™ algorithms in reducing bradycardia and pause detection: real-world performance in Confirm Rx™ insertable cardiac monitor.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022
    Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Christopher PiorkowskiDepartment of Invasive Electrophysiology, Heart Center Dresden, Dresden, Germany.
Mathias BuschDepartment of Internal Medicine B, Greifswald University Hospital, Greifswald, Germany.
Georg NölkerClinic for Cardiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
Jörn SchmittDepartment of Cardiology, University Hospital Giessen, Giessen, Germany.
Franz Xaver RoithingerDepartment of Inner Medicine, Landesklinikum Mödling, Mödling, Austria.
Glenn YoungDepartment of Cardiology, St. Andrew's Hospital, Adelaide, South Australia, Australia.
Miloš TáborskýDepartment of Internal Medicine-Cardiology, University Hospital Olomouc, Olomouc, Czech Republic.
Gundula HerrmannCenter of Clinical Research, Biotronik SE & Co. KG, Berlin, Germany.ORCID 0000-0003-1571-2628
Dietmar SchmitzClinic for Cardiology and Angiology, St. Elisabeth Hospital Essen, Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWe conducted this study to show the safety and efficacy of a new implantable cardiac monitor (ICM), the BioMonitor 2 (Biotronik SE & Co. KG; Berlin, Germany), and to describe the arrhythmia detection performance.

methodsThe BioMonitor 2 has an extended sensing vector and is implanted close to the heart. It can transmit up to six subcutaneous electrocardiogram strips by Home Monitoring each day. We enrolled 92 patients with a standard device indication for an ICM in a single-arm, multicenter prospective trial. Patients were followed for 3 months, and 48-h Holter recordings were used to evaluate the arrhythmia detection performance.

resultsOne patient withdrew consent and in one patient, the implantation failed. Two study device-related serious adverse events were reported, satisfying the primary safety hypothesis. Implantations took 7.4 ± 4.4 min from skin cut to suture. At 1 week, the R-wave amplitude was 0.75 ± 0.53 mV. In the 82 patients with completed Holter recordings, all patients with arrhythmias were correctly identified. False positive detections of arrhythmia were mostly irregular rhythms wrongly detected as atrial fibrillation (episode-based positive predictive value 72.5%). Daily Home Monitoring transmission was 94.9% successful.

conclusionSafety and efficacy of the new device has been demonstrated. The detected R-wave amplitudes are large, leading to a low level of inappropriate detections due to over- or undersensing.

Indexed as

Arrhythmias, CardiacElectrocardiography, AmbulatoryEquipment DesignFemaleHumansMaleMiddle AgedProspective Studiesarrhythmia detectionatrial fibrillationimplantable cardiac monitorremote monitoringsyncope

Identifiers

PMID31119745
PMCPMC6851891

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.