ArticleInternal medicine (Tokyo, Japan)2019
A Low Critical Event Rate Despite a High Abnormal Event Rate in Patients with Cardiac Implantable Electric Devices Followed Up by Remote Monitoring.
Article in Internal medicine (Tokyo, Japan), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- International survey of cardiac device clinic staff determining patient-perceived challenges with remote monitoring.Acta cardiologica · 2025Article
- Current clinical practice versus remote monitoring recommendations for cardiovascular implantable electronic devices: A real-world analysis from a remote monitoring database.Heart rhythm O2 · 2025Article
- Artificial intelligence to detect noise events in remote monitoring data.Journal of arrhythmia · 2024Article
- 2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic.Journal of arrhythmia · 2023Article
- 2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023Article
- Remote Patient Monitoring: What Have We Learned and Where Are We Going?Current cardiovascular risk reports · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective Remote monitoring (RM) of cardiac implantable electric devices (CIEDs) has been advocated as a healthcare standard. However, expert consensus statements suggest that all patients require annual face-to-face follow-up consultations at outpatient clinics even if RM reveals no episodes. The objective of this study was to determine the critical event rate after CIED implantation through RM. Methods This multicenter, retrospective, cohort study evaluated patients with pacemakers (PMs), implantable cardioverter defibrillators (ICDs), or cardiac resynchronization therapy defibrillator (CRT-Ds) and analyzed whether or not the data drawn from RM included abnormal or critical events. Patients A total of 1,849 CIED patients in 12 hospitals who were followed up by the RM center in Okayama University Hospital were included in this study. Results During the mean follow-up period of 774.9 days, 16,560 transmissions were analyzed, of which 11,040 (66.7%) were abnormal events and only 676 (4.1%) were critical events. The critical event rate in the PM group was significantly lower than that in the ICD or CRT-D groups (0.9% vs. 5.0% or 5.9%, p<0.001). A multivariate analysis revealed that ICD, CRT-D, and a low ejection fraction were independently associated with critical events. In patients with ICD, the independent risk factors for a critical event were old age, low ejection fraction, Brugada syndrome, dilated phase hypertrophic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy. Conclusion Although abnormal events were observed in two-thirds of the transmitted RM data, the critical event rate was <1% in patients with a PM, which was lower in comparison to the rates in patients with ICDs or CRT-Ds. A low ejection fraction was an independent predictor of critical events.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.