ArticlePhysics in medicine and biology2019
Two-crossed-polarizers based optical property modulation method for ionizing radiation detection for positron emission tomography.
Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 14 citations in OpenAlex.
- Development and Characterization of Modular Readout Design for Two-Panel Head-and-Neck Dedicated PET System Based on CZT Detectors.IEEE transactions on radiation and plasma medical sciences · 2022Article
- Reduction of the Low Energy Threshold through New Modular Data Acquisition Electronics for Cross-strip Cadmium Zinc Telluride (CZT) based PET System.IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium · 2021Article
- Optical Simulation and Experimental Assessment with Time-Walk Correction of TOF-PET Detectors with Multi-Ended Readouts.Sensors (Basel, Switzerland) · 2021Article
- Further investigations of a radiation detector based on ionization-induced modulation of optical polarization.Physics in medicine and biology · 2021Article
- Back-end readout electronic design and initial results: a head-and-neck dedicated PET system based on CZT.Proceedings of SPIE--the International Society for Optical Engineering · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
Abstract
Recent work shows that Pockels effect and optics pump-probe measurement could be utilized as a novel method for 511 keV ionizing radiation photon detection for positron emission tomography (PET) which could potentially overcome the inherent physical limitation for coincidence time resolution of around 100 ps (Tao et al 2016 Phys. Med. Biol. 61 7600-22). In this paper, we embrace this observation and introduce a two-crossed-polarizers based setup to achieve similar detection concept, which is a simpler and more compact setup with comparable ionizing radiation detection capability as the setup used in the previously proposed work. We evaluated the performance of our experimental setup with Lithium Niobate (LiNbO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.