Evidence map›Paper›PMID 31115768›Full record

ArticleJournal of medical systems2019

Based Medical Systems for Patient's Authentication: Towards a New Verification Secure Framework Using CIA Standard.

A H Mohsin, A A Zaidan, B B Zaidan, O S Albahri, A S Albahri, M A Alsalem, K I Mohammed

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

A H MohsinDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia.
A A ZaidanDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia. aws.alaa@gmail.com.
B B ZaidanDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia.
O S AlbahriDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia.
A S AlbahriDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia.
M A AlsalemDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia.
K I MohammedDepartment of Computing, Universiti Pendidikan Sultan Idris, Tanjong Malim, Perak, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In medical systems for patient's authentication, keeping biometric data secure is a general problem. Many studies have presented various ways of protecting biometric data especially finger vein biometric data. Thus, It is needs to find better ways of securing this data by applying the three principles of information security aforementioned, and creating a robust verification system with high levels of reliability, privacy and security. Moreover, it is very difficult to replace biometric information and any leakage of biometrics information leads to earnest risks for example replay attacks using the robbed biometric data. In this paper presented criticism and analysis to all attempts as revealed in the literature review and discussion the proposes a novel verification secure framework based confidentiality, integrity and availability (CIA) standard in triplex blockchain-particle swarm optimization (PSO)-advanced encryption standard (AES) techniques for medical systems patient's authentication. Three stages are performed on discussion. Firstly, proposes a new hybrid model pattern in order to increase the randomization based on radio frequency identification (RFID) and finger vein biometrics. To achieve this, proposed a new merge algorithm to combine the RFID features and finger vein features in one hybrid and random pattern. Secondly, how the propose verification secure framework are followed the CIA standard for telemedicine authentication by combination of AES encryption technique, blockchain and PSO in steganography technique based on proposed pattern model. Finally, discussed the validation and evaluation of the proposed verification secure framework.

Indexed as

Computer SystemsSecurity MeasuresBiometric IdentificationFingersHumansPatient Identification SystemsRadio Frequency Identification DeviceReference StandardsRemote Sensing TechnologyTelemedicineAuthenticationBiometricBlockchainFinger veinmHealthReal-time remote health monitoring systemSecuritySteganographyTelemedicine

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.