Evidence map›Paper›PMID 31113423›Full record

ArticleBiomedical engineering online2019

Is there any advantage of using stand-alone cages? A numerical approach.

Andrea Calvo-Echenique, José Cegoñino, Amaya Perez Del Palomar

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Andrea Calvo-EcheniqueGroup of Biomaterials, Aragón Institute of Engineering Research (I3A), Mechanical Engineering Department, University of Zaragoza, C/Maria de Luna s/n. Betancourt Building, 50018, Saragossa, Spain.
José CegoñinoGroup of Biomaterials, Aragón Institute of Engineering Research (I3A), Mechanical Engineering Department, University of Zaragoza, C/Maria de Luna s/n. Betancourt Building, 50018, Saragossa, Spain.
Amaya Perez Del PalomarGroup of Biomaterials, Aragón Institute of Engineering Research (I3A), Mechanical Engineering Department, University of Zaragoza, C/Maria de Luna s/n. Betancourt Building, 50018, Saragossa, Spain. amaya@unizar.es.ORCID http://orcid.org/0000-0003-0669-777X
Universidad de Zaragoza · ES

Funding

Ministerio de Economía, Industria y Competitividad, Gobierno de España DPI2016-79302R
6 · The paper itself

Abstract

backgroundSegment fusion using interbody cages supplemented with pedicle screw fixation is the most common surgery for the treatment of low back pain. However, there is still much controversy regarding the use of cages in a stand-alone fashion. The goal of this work is to numerically compare the influence that each surgery has on lumbar biomechanics.

methodsA non-linear FE model of the whole lumbar spine was developed to compare between two types of cages (OLYS and NEOLIF) with and without supplementary fixation. The motion of the whole spine was analysed and the biomechanical environment of the adjacent segments to the operated one was studied. Moreover, the risk of subsidence of the cages was qualitatively evaluated.

resultsA great ROM reduction occurred when supplementary fixation was used. This stiffening increased the stresses at the adjacent levels. It might be hypothesised that the overloading of these segments could be related with the clinically observed adjacent disc degeneration. Meanwhile, the stand-alone cages allowed for a wider movement, and therefore, the influence of the surgery on adjacent discs was much lower. Regarding the risk of subsidence, the contact pressure magnitude was similar for both intervertebral cage designs and near the value of the maximum tolerable pressure of the endplates.

conclusionsA minimally invasive posterior insertion of an intervertebral cage (OLYS or NEOLIF) was compared using a stand-alone design or adding supplementary fixation. The outcomes of these two techniques were compared, and although stand-alone cage may diminish the risk of disease progression to the adjacent discs, the spinal movement in this case could compromise the vertebral fusion and might present a higher risk of cage subsidence.

Indexed as

Finite Element AnalysisPedicle ScrewsBiomechanical PhenomenaLow Back PainLumbar VertebraeRiskSpinal FusionTreatment OutcomeFinite element methodIntervertebral discLumbar spinePosterior lumbar interbody fusionPosterior screw fixationStand-alone cages

Identifiers

PMID31113423
PMCPMC6530002
OpenAlexW2947555346

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked