ArticleJournal of applied clinical medical physics2019
Development of a rotational set-up correction device for stereotactic head radiation therapy: A performance evaluation.
Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- The Usefulness of a Virtual Environment-Based Patient Setup Training System for Radiation Therapy.Journal of imaging · 2024Article
- Evaluation of a head rest prototype for rotational corrections in three degrees of freedom.Journal of applied clinical medical physics · 2024Article
- Treatment plan comparison for irradiation of multiple brain metastases with hippocampal avoidance whole brain radiotherapy and simultaneous integrated boost using the Varian Halcyon and the Elekta Synergy platforms.Radiation oncology (London, England) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We developed a new head supporting device to provide accurate correction of rotational setup during image-guided radiation therapy (IGRT), evaluating its correction performance and the efficacy of dose distribution in stereotactic radiotherapy (SRT) using a helical tomotherapy (HT) system. The accuracy of rotational motion was measured using an electronic inclinometer; we compared device angles and measurement values from 0.0° to 3.0°. The correction accuracy was investigated based on the distance between rotational centers in the device and on megavoltage computed tomography (MVCT); the correction values were compared using distances in the range of 0.0-9.0 cm using a head phantom with a rotational error of 1.5°. For an SRT with a simultaneous integrated boost plan and a rotational error of 3.0° in yaw angle using a head phantom, and for a single-isocenter SRT for multiple brain metastases in the data of three patients, dosimetric efficacy of the HT unit was evaluated for calculated dose distributions with MVCT after rotational correction. This device can correct pitch and yaw angles within 0.3° and can be corrected to within 0.5° for each rotational angle according to the result of MVCT correction regardless of the rotational center position. In the head phantom study, the device had a beneficial impact on rotational correction; D99% for the target improved by approximately 10% with rotational correction. Using patient data with the device, the mean difference based on the treatment planning data was 0.3% for D99% and -0.1% for coverage index to the target. Our rotational setup correction device has high efficacy, and can be used for IGRT.