ArticleMedical physics2019
MRI-only based synthetic CT generation using dense cycle consistent generative adversarial networks.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 132 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
132 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A systematic literature review: deep learning techniques for synthetic medical image generation and their applications in radiotherapy.Frontiers in radiology · 2024Pooled it
- Improving deep-learning IMRT plan quality for lymphoma using deliverability-aware training.Journal of applied clinical medical physics · 2026Article
- Evaluation-design effects and reference-CT-defined HU-class errors in brain MRI-to-CT synthesis on SynthRAD2023: a technical note.Radiological physics and technology · 2026Article
- Image-based evaluation of a commercial AI synthetic CT generator for brain and prostate MR-only radiotherapy.Journal of applied clinical medical physics · 2026Article
- Paired CycleGAN-based virtual staining for 3D X-ray histology of bone-implant systems.Journal of synchrotron radiation · 2026Article
- AI in Musculoskeletal Imaging: An End-to-End Perspective.Journal of clinical medicine · 2026Review
- Exploration of Deep Learning Methods for Synthetic T2-Weighted Pelvic MRI Generation from CT Scans: A Technical Feasibility Study.Journal of imaging informatics in medicine · 2026Article
- Synthesize contrast-enhanced ultrasound image of thyroid nodules via generative adversarial networks.European radiology · 2026Article
- Image registration using MR-based synthetic CT (sCT) generated by cycle-consistent adversarial networks.Biomedical engineering letters · 2026Article
- Generation of multimodal realistic computational phantoms as a test-bed for validating deep learning-based cross-modality synthesis techniques.Medical & biological engineering & computing · 2026Article
- A review of image processing and analysis of computed tomography images using deep learning methods.Physical and engineering sciences in medicine · 2025Review
- 3D Latent Diffusion Model for MR-Only Radiotherapy: Accurate and Consistent Synthetic CT Generation.Diagnostics (Basel, Switzerland) · 2025Article
- Enhancing Radiographic Diagnosis: CycleGAN-Based Methods for Reducing Cast Shadow Artifacts in Wrist Radiographs.Journal of imaging informatics in medicine · 2025Article
- The Role of Artificial Intelligence in Advancing Theranostics Dosimetry for Cancer Therapy: a Review.Nuclear medicine and molecular imaging · 2025Review
- Systematic Review and Meta-analysis of AI-driven MRI Motion Artifact Detection and Correction.ArXiv · 2025Article
- Decision support using machine learning for predicting adequate bladder filling in prostate radiotherapy: a feasibility study.Radiological physics and technology · 2025Article
- A comprehensive comparative study of generative adversarial network architectures for synthetic computed tomography generation in the abdomen.Medical physics · 2025Article
- Evaluation of model uncertainty in AI-based synthetic CT generation from CBCT for abdominal adaptive radiotherapy.Medical physics · 2025Article
- Recent topics in musculoskeletal imaging focused on clinical applications of AI: How should radiologists approach and use AI?La Radiologia medica · 2025Review
- T1-contrast enhanced MRI generation from multi-parametric MRI for glioma patients with latent tumor conditioning.Medical physics · 2025Article
72 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeAutomated synthetic computed tomography (sCT) generation based on magnetic resonance imaging (MRI) images would allow for MRI-only based treatment planning in radiation therapy, eliminating the need for CT simulation and simplifying the patient treatment workflow. In this work, the authors propose a novel method for generation of sCT based on dense cycle-consistent generative adversarial networks (cycle GAN), a deep-learning based model that trains two transformation mappings (MRI to CT and CT to MRI) simultaneously. METHODS AND MATERIALS: The cycle GAN-based model was developed to generate sCT images in a patch-based framework. Cycle GAN was applied to this problem because it includes an inverse transformation from CT to MRI, which helps constrain the model to learn a one-to-one mapping. Dense block-based networks were used to construct generator of cycle GAN. The network weights and variables were optimized via a gradient difference (GD) loss and a novel distance loss metric between sCT and original CT.
resultsLeave-one-out cross-validation was performed to validate the proposed model. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross correlation (NCC) indexes were used to quantify the differences between the sCT and original planning CT images. For the proposed method, the mean MAE between sCT and CT were 55.7 Hounsfield units (HU) for 24 brain cancer patients and 50.8 HU for 20 prostate cancer patients. The mean PSNR and NCC were 26.6 dB and 0.963 in the brain cases, and 24.5 dB and 0.929 in the pelvis.
conclusionWe developed and validated a novel learning-based approach to generate CT images from routine MRIs based on dense cycle GAN model to effectively capture the relationship between the CT and MRIs. The proposed method can generate robust, high-quality sCT in minutes. The proposed method offers strong potential for supporting near real-time MRI-only treatment planning in the brain and pelvis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials