Evidence map›Paper›PMID 31111862›Full record

Trial reportJAMA cardiology2019

Outcomes in Patients Treated With Thin-Strut, Very Thin-Strut, or Ultrathin-Strut Drug-Eluting Stents in Small Coronary Vessels: A Prespecified Analysis of the Randomized BIO-RESORT Trial.

Rosaly A Buiten, Eline H Ploumen, Paolo Zocca, Carine J M Doggen, Liefke C van der Heijden, Marlies M Kok, Peter W Danse, Carl E Schotborgh, Martijn Scholte, Frits H A F de Man and 2 more

2 registry-linked trialsOpen access · greenAbstract readMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in JAMA cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 38 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed, 1 pooled it
10.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01674803 nacompletednot on this map

Comparison of BIOdegradable Polymer and DuRablE Polymer Drug-eluting Stents in an All COmeRs PopulaTion: Randomized Multicenter Trial in an All Comers Population Treated Within thE NeThErlands 3 (TWENTE 3)

TypeinterventionalSponsorFoundation of Cardiovascular Research and Education EnschedeRan2012 to 2020Enrolled3,514ConditionsAcute Coronary Syndrome, Angina Pectoris, Angina, Unstable, Myocardial InfarctionArmsOrsiro, Synergy, Resolute Integrity
NCT05094284 recruitingnot on this mapstarted 2021, after this paper: background citation

BioFreedom Ultra Stent in Hong Kong All Comers Registry

Typeobservational_patient_registrySponsorChinese University of Hong KongRan2021 to 2028Enrolled300ConditionsCoronary Artery DiseaseArmsBioFreedom Ultra
3 · Its place in the literature

Who cites it

38 citing papers in PubMed, 1 synthesis or guideline pooled it, 70 citations in OpenAlex.

  1. Clinical outcomes of percutaneous coronary intervention forFrontiers in cardiovascular medicine · 2022
    Pooled it
  2. Trial
  3. Trial
  4. Individual patient data analysis of the BIOFLOW study program comparing safety and efficacy of a bioresorbable polymer sirolimus eluting stent to a durable polymer everolimus eluting stent.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021
    Trial
  5. BioMatrix versus Orsiro biodegradable polymer stents in all-comer patients with coronary artery disease: the multicentre, randomised BIODEGRADE trial.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2021
    Trial
  6. Impact of Strut Thickness for Patients Treated With Percutaneous Revascularization for Coronary Bifurcations: Insights From the BIFURCAT-ULTRA Registry.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  7. Article
  8. Article
  9. Early Postpartum IL-10 and IL-37 Concentrations in Women with Gestational Diabetes Mellitus.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  10. Article
  11. Article
  12. Review
  13. Is this the end of the ultrathin-strut hypothesis?EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Article
  14. Observational
  15. Drug-coated balloons as a first choice for patients with de novo lesions: pros and cons.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors at 6 institutions in 1 country.

Rosaly A BuitenDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Eline H PloumenDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Paolo ZoccaDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Carine J M DoggenDepartment of Health Technology and Services Research, Faculty BMS, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
Liefke C van der HeijdenDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Marlies M KokDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Peter W DanseDepartment of Cardiology, Rijnstate Hospital, Arnhem, the Netherlands.
Carl E SchotborghDepartment of Cardiology, Haga Hospital, The Hague, the Netherlands.
Martijn ScholteDepartment of Cardiology, Albert Schweitzer Hospital, Dordrecht, the Netherlands.
Frits H A F de ManDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Gerard C M LinssenDepartment of Cardiology, Hospital Group Twente, Almelo and Hengelo, the Netherlands.
Clemens von BirgelenDepartment of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
Medisch Spectrum Twente · NLUniversity of Twente · NLAlbert Schweitzer Ziekenhuis · NLHaga Hospital · NLRijnstate Hospital · NLZiekenhuis Groep Twente · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Stenting small-vessel lesions has an increased adverse cardiovascular event risk. Very thin-strut or ultrathin-strut drug-eluting stents might reduce this risk, but data are scarce. Objective: To assess the outcome of all-comer patients with small coronary vessel lesions treated with 3 dissimilar types of drug-eluting stents. Design: This is a prespecified substudy of the Comparison of Biodegradable Polymer and Durable Polymer Drug-eluting Stents in an All Comers Population (BIO-RESORT) trial, an investigator-initiated, randomized, patient-blinded comparative clinical drug-eluting stent trial. Patients treated with ultrathin-strut sirolimus-eluting stents, very thin-strut everolimus-eluting stents, or previous-generation thin-strut zotarolimus-eluting stents were enrolled from December 2012 to August 2015. This multicenter trial was conducted in 4 Dutch centers for cardiac intervention. Of all 3514 all-comer BIO-RESORT participants, 1506 patients with treatment in at least 1 small-vessel lesion (reference vessel <2.5 mm) were included. Data were analyzed between September 2018 and February 2019. Main Outcomes and Measures: Target lesion failure at 3-year follow-up, a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization, analyzed by Kaplan-Meier methods. Results: In 1452 of 1506 participants (96.4%) (1057 men [70.2%]; 449 women [29.8%]; mean [SD] age, 64.3 [10.4] years), follow-up was available. Target lesion failure occurred in 36 of 525 patients (7.0%) treated with sirolimus-eluting stents, 46 of 496 (9.5%) with everolimus-eluting stents, and 48 of 485 (10.0%) with zotarolimus-eluting stents (sirolimus-eluting vs zotarolimus-eluting hazard ratio [HR], 0.68; 95% CI, 0.44-1.05; P = .08; everolimus-eluting vs zotarolimus-eluting HR, 0.93; 95% CI, 0.62-1.39; P = .72). There was a difference in target lesion revascularizations between sirolimus-eluting and zotarolimus-eluting stents (2.1% vs 5.3%; HR, 0.40; 95% CI, 0.20-0.81; P = .009) that emerged after the first year of follow-up (1.0% vs 3.7%; P = .006); multivariate analysis showed that sirolimus-eluting stent implantation was independently associated with a lower target lesion revascularization rate at 3-year follow-up (adjusted HR, 0.42; 95% CI, 0.20-0.85; P = .02). In the everolimus-eluting stents, the revascularization rate was 4.0% (vs zotarolimus-eluting, HR, 0.74; 95% CI, 0.41-1.34; P = .31). There was no significant between-stent difference in cardiac death, target vessel myocardial infarction, or stent thrombosis. Conclusions and Relevance: Patients stented in small coronary vessels experienced fewer repeated revascularizations if treated with ultrathin-strut sirolimus-eluting stents vs previous generation thin strut zotarolimus-eluting stents. Further research is required to evaluate the potential effect of particularly thin stent struts. Trial Registration: ClinicalTrials.gov identifier: NCT01674803.

Indexed as

Drug-Eluting StentsAbsorbable ImplantsCoronary RestenosisCoronary VesselsEverolimusFemaleHumansImmunosuppressive AgentsMaleMiddle AgedMyocardial InfarctionPercutaneous Coronary InterventionProsthesis DesignRisk FactorsSirolimusTreatment OutcomeEverolimusImmunosuppressive AgentsSirolimuszotarolimus

Identifiers

PMID31111862
PMCPMC6537851
OpenAlexW2944889323

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.