ArticleZoological letters2019
X-ray imaging of a water bear offers a new look at tardigrade internal anatomy.
Article in Zoological letters, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 35 citations in OpenAlex.
- A Non-Invasive, Label-Free Method for Examining Tardigrade Anatomy Using Holotomography.Tomography (Ann Arbor, Mich.) · 2025Article
- Pigment-dispersing factor neuropeptides act as multifunctional hormones and modulators in tardigrades.Open biology · 2025Article
- Fluorescence shadow imaging of Hypsibius exemplaris reveals morphological differences between sucrose- and CaClScientific reports · 2024Article
- The tardigrade Hypsibius exemplaris dramatically upregulates DNA repair pathway genes in response to ionizing radiation.Current biology : CB · 2024Article
- Storage cell proliferation during somatic growth establishes that tardigrades are not eutelic organisms.Biology open · 2024Article
- Natural variability in bee brain size and symmetry revealed by micro-CT imaging and deep learning.PLoS computational biology · 2023Article
- Polarization-sensitive intensity diffraction tomography.Light, science & applications · 2023Article
- A multiscale approach reveals elaborate circulatory system and intermittent heartbeat in velvet worms (Onychophora).Communications biology · 2023Article
- The Embryonic Origin of Primordial Germ Cells in the TardigradebioRxiv : the preprint server for biology · 2023Article
- How long can tardigrades survive in the anhydrobiotic state? A search for tardigrade anhydrobiosis patterns.PloS one · 2023Article
- When SEM becomes a deceptive tool of analysis: the unexpected discovery of epidermal glands with stalked ducts on the ultimate legs of geophilomorph centipedes.Frontiers in zoology · 2021Article
- Tolerance to Anhydrobiotic Conditions Among Two Coexisting Tardigrade Species Differing in Life Strategies.Zoological studies · 2021Article
- Introducing Biomedisa as an open-source online platform for biomedical image segmentation.Nature communications · 2020Article
- Nanoscopic X-ray tomography for correlative microscopy of a small meiofaunal sea-cucumber.Scientific reports · 2020Article
- Functional morphology of a lobopod: case study of an onychophoran leg.Royal Society open science · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTardigrades (water bears) are microscopic invertebrates of which the anatomy has been well studied using traditional techniques, but a comprehensive three-dimensional reconstruction has never been performed. In order to close this gap, we employed X-ray computed tomography (CT), a technique that is becoming increasingly popular in zoology for producing high-resolution, three-dimensional (3D) scans of whole specimens. While CT has long been used to scan larger samples, its use in some microscopic animals can be problematic, as they are often too small for conventional CT yet too large for high-resolution, optics-based soft X-ray microscopy. This size gap continues to be narrowed with advancements in technology, with high-resolution imaging now being possible using both large synchrotron devices and, more recently, laboratory-based instruments.
resultsHere we use a recently developed prototype lab-based nano-computed tomography device to image a 152 μm-long tardigrade at high resolution (200-270 nm pixel size). The resulting dataset allowed us to visualize the anatomy of the tardigrade in 3D and analyze the spatial relationships of the internal structures. Segmentation of the major structures of the body enabled the direct measurement of their respective volumes. Furthermore, we segmented every storage cell individually and quantified their volume distribution. We compare our measurements to those from published studies in which other techniques were used.
conclusionsThe data presented herein demonstrate the utility of CT imaging as a powerful supplementary tool for studies of tardigrade anatomy, especially for quantitative volume measurements. This nanoCT study represents the smallest complete animal ever imaged using CT, and offers new 3D insights into the spatial relationships of the internal organs of water bears.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.