Evidence map›Paper›PMID 31105515›Full record

ArticleFrontiers in neuroscience2019

Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies.

Vijay Viswam, Marie Engelene J Obien, Felix Franke, Urs Frey, Andreas Hierlemann

Abstract read
In one paragraph

Article in Frontiers in neuroscience, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 53 papers.

0numbers the graph read from it
0cells of the map it votes in
53citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

53 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Vijay ViswamDepartment of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland.
Marie Engelene J ObienDepartment of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland.
Felix FrankeDepartment of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland.
Urs FreyDepartment of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland.
Andreas HierlemannDepartment of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Advances in microfabrication technology have enabled the production of devices containing arrays of thousands of closely spaced recording electrodes, which afford subcellular resolution of electrical signals in neurons and neuronal networks. Rationalizing the electrode size and configuration in such arrays demands consideration of application-specific requirements and inherent features of the electrodes. Tradeoffs among size, spatial density, sensitivity, noise, attenuation, and other factors are inevitable. Although recording extracellular signals from neurons with planar metal electrodes is fairly well established, the effects of the electrode characteristics on the quality and utility of recorded signals, especially for small, densely packed electrodes, have yet to be fully characterized. Here, we present a combined experimental and computational approach to elucidating how electrode size, and size-dependent parameters, such as impedance, baseline noise, and transmission characteristics, influence recorded neuronal signals. Using arrays containing platinum electrodes of different sizes, we experimentally evaluated the electrode performance in the recording of local field potentials (LFPs) and extracellular action potentials (EAPs) from the following cell preparations: acute brain slices, dissociated cell cultures, and organotypic slice cultures. Moreover, we simulated the potential spatial decay of point-current sources to investigate signal averaging using known signal sources. We demonstrated that the noise and signal attenuation depend more on the electrode impedance than on electrode size,

Indexed as

electrode sizeextracellular action potentialextracellular recordingimpedancelocal field potentialmicroelectrode array

Identifiers

PMID31105515
PMCPMC6498989

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.