Evidence map›Paper›PMID 31097906›Full record

ArticleJSLS : Journal of the Society of Laparoendoscopic Surgeons

Laparoscopic Insertion of Various Shaped Trocars in a Porcine Model.

Danilo Galante Moreno, Cesar Augusto Martins Pereira, Ricardo Kyoiti Sant Anna, Rafael Ulysses de Azevedo, Luiz Felipe Savio, Ricardo Jordão Duarte, Miguel Srougi, Carlo Camargo Passerotti

Open access · hybridAbstract read
In one paragraph

Article in JSLS : Journal of the Society of Laparoendoscopic Surgeons. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Danilo Galante MorenoLaboratory of Medical Research, Department of Urology, University of Sao Paulo, São Paulo, Brazil.
Cesar Augusto Martins PereiraLaboratory of Medical Research, Department of Urology, University of Sao Paulo, São Paulo, Brazil.
Ricardo Kyoiti Sant AnnaCenter for Robotic Surgery, Oswaldo Cruz German Hospital, São Paulo, Brazil.
Rafael Ulysses de AzevedoCenter for Robotic Surgery, Oswaldo Cruz German Hospital, São Paulo, Brazil.
Luiz Felipe SavioCenter for Robotic Surgery, Oswaldo Cruz German Hospital, São Paulo, Brazil.
Ricardo Jordão DuarteLaboratory of Medical Research, Department of Urology, University of Sao Paulo, São Paulo, Brazil.
Miguel SrougiLaboratory of Medical Research, Department of Urology, University of Sao Paulo, São Paulo, Brazil.
Carlo Camargo PasserottiLaboratory of Medical Research, Department of Urology, University of Sao Paulo, São Paulo, Brazil.
Universidade de São Paulo · BRHospital Alemão Oswaldo Cruz · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectiveThe number of laparoscopic procedures increases annually with an estimated 3% of complications, one third of them linked to Verres' needle or trocar insertion. The safety and efficacy of ports insertion during laparoscopic surgery may be related the technique but also to trocar design. This study aims to compare physical parameters of abdominal wall penetration for 5 different trocars.

methodsEleven pigs were studied. Five different commercially available trocars were randomically inserted at the midline. Real-time video recording of the insertions was achieved to measure the excursion of the abdominal wall and the time and distance the cutting surface of the bladed trocars was exposed inside the abdominal cavity. An especially designed hand sensor was developed and placed between the trocar and the hand of the surgeon to record force required for abdominal wall perforation.

resultsGreater deformations and forces occurred in nonbladed as compared to bladed trocars, and in conical trocars as compared to pyramidal pointed ones, except for peritoneum perforation. Greater distance and time of blade exposure occurred in pyramidal laminae as compared to conical.

conclusionThe bladed trocars have lower forces and deformations in their introduction, and should be those that cause less injury and are more suitable for first entry. Conical and pyramidal trocars with the same blade size showed similar force, deformation, time, and distance of exposed blade.

Indexed as

Abdominal WallAnimalsEquipment DesignLaparoscopyModels, AnimalSwineAnimal modelLaparoscopySafetyTrocar

Identifiers

PMID31097906
PMCPMC6476561
OpenAlexW2946335754

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.