Evidence map›Paper›PMID 31092237›Full record

ArticleBMC musculoskeletal disorders2019

Application of an interspinous process device after minimally invasive lumbar decompression could lead to stress redistribution at the pars interarticularis: a finite element analysis.

Hao-Ju Lo, Chen-Sheng Chen, Hung-Ming Chen, Sai-Wei Yang

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 22 citations in OpenAlex.

  1. Impact of vertebrae shape variation on lumbar spine loading: an image-based computational modeling study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. [Biomechanical study of different approach for lumbar interbody fusion surgeries under vibration load].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021
    Article
  7. Article
  8. Biomechanical analysis of lumbar interbody fusion supplemented with various posterior stabilization systems.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Hao-Ju LoDepartment of Biomedical Engineering, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 11221, Taiwan.
Chen-Sheng ChenDepartment of Physical Therapy and Assistive Technology, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 11221, Taiwan.
Hung-Ming ChenDepartment of Orthopedic Surgery, Renai Branch, Taipei City Hospital, No. 10, Section 4, Ren'ai Road, Da'an District, Taipei City, 106, Taiwan.
Sai-Wei YangDepartment of Biomedical Engineering, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 11221, Taiwan. swyang@ym.edu.tw.ORCID http://orcid.org/0000-0001-6488-2741
National Yang Ming Chiao Tung University · TWTaipei City Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn interspinous process device, the Device for Intervertebral Assisted Motion (DIAM™) designed to treat lumbar neurogenic disease secondary to the lumbar spinal stenosis, it provides dynamic stabilization after minimally invasive (MI) lumbar decompression. The current study was conducted using an experimentally validated L1-L5 spinal finite element model (FEM) to evaluate the limited decompression on range of motion (ROM) and stress distribution on a neural arch implanted with the DIAM.

methodsThe study simulated bilateral laminotomies with partial discectomy at L3-L4, as well as unilateral and bilateral laminotomies with partial discectomy combined with implementation of the DIAM at L3-L4. The ROM and maximum von Mises stresses in flexion, extension, lateral bending, and axial torsion were analyzed in response to the hybrid protocol in comparison with the intact model.

resultsThe investigation revealed that decreased ROM, intradiscal stress, and facet joint force at the implant level, but considerably increased stress at the pars interarticularis were found during flexion and torsion at the L4, as well as during extension, lateral bending, and torsion at the L3, when the DIAM was implanted compared with the defect model.

conclusionThe results demonstrate that the DIAM may be beneficial in reducing the symptoms of stress-induced low back pain. Nevertheless, the results also suggest that a surgeon should be cognizant of the stress redistribution at the pars interarticularis results from MI decompression plus the application of the interspinous process device.

Indexed as

Models, BiologicalProstheses and ImplantsDiskectomyFeasibility StudiesFinite Element AnalysisHumansIntervertebral DiscLaminectomyLumbar VertebraeProsthesis ImplantationRange of Motion, ArticularSpinal StenosisStress, MechanicalFinite element modelInterspinous process deviceMinimally invasivePars interarticularis

Identifiers

PMID31092237
PMCPMC6518805
OpenAlexW2947912006

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.