Pelvic discontinuity in acetabular revisions: does CT scan overestimate it? A comparative study of diagnostic accuracy of 3D-modeling and traditional 3D CT scan.

A Aprato, M Olivero, G Iannizzi, A Bistolfi, L Sabatini, A Masse

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Musculoskeletal surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Observational
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Decision/therapeutic algorithm for acetabular revisions.Acta bio-medica : Atenei Parmensis · 2020
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

A ApratoUniversity of Turin, Turin, Italy. ale_aprato@hotmail.com.ORCID http://orcid.org/0000-0002-2514-4719
M OliveroUniversity of Turin, Turin, Italy.
G IannizziMedics Srl, Turin, Italy.
A BistolfiUniversity of Turin, Turin, Italy.
L SabatiniUniversity of Turin, Turin, Italy.
A MasseUniversity of Turin, Turin, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purpose3D CT scan is actually the gold standard for preoperative diagnosis of pelvic discontinuity (PD) in hip revision surgery. Aim of this study was to compare the accuracy of 3D-modeling with traditional and 3D CT scan. MATERIALS AND

methodsWe retrospectively identified 56 patients who underwent total hip arthroplasty revisions with Paprosky Type-3 periacetabular bone defects. Preoperative X-rays, CT scans and 3D-models were blindly reviewed by two orthopedic surgeons to detect possible pelvic discontinuities. Results were compared with surgical notes. Independent sensitivities, specificities, positive predictive values and negative predictive values were calculated for X-rays, CT scan and 3D models. Analysis of interobserver reliability was performed.

resultsFifty-six patients met inclusion criteria. In nine patients, surgical notes indicated a pelvic discontinuity. On 3D CT scans, PD was identified in 25 cases for observer 1 and in 24 cases for observer 2. Analyzing 3D-models, PD was identified in eleven patients by both observers. The nine patients, with PD reported on the surgical report, were all identified with both the techniques. The specificity of standard 3D CT was 0.66 for observer 1 and 0.68 for observer 2 and increased to 0.96 for both observers with the utilization of 3D-models. The positive predictive value increased from 0.36 (observer 1) and 0.38 (observer 2) with the CT evaluation to 0.82 in the 3D-models evaluation. The analysis of 3D models was characterized by a perfect intraobserver reliability (intraobserver correlation coefficient = 1). The observers showed substantial agreement for PD classification; the kappa values were 0.96 and 0.77, respectively, for CT scan and 3D-model evaluation.

conclusions3D-modeling showed higher specificity than traditional and 3D CT scans in identification of PD in Paprosky Type-3 periacetabular bone defects.

Indexed as

Arthroplasty, Replacement, HipImaging, Three-DimensionalTomography, X-Ray ComputedAcetabulumAgedFemaleHumansMaleModels, AnatomicObserver VariationOsteolysisPelvic BonesPostoperative ComplicationsPredictive Value of TestsReoperationRetrospective Studies3D modelingAcetabular revisionsBone lossCT scanPelvic discontinuity

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.