Evidence map›Paper›PMID 31089749›Full record

ReviewDer Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen2019

[Standardized access options for colorectal surgery with the da Vinci Xi system].

D Perez, A Woestemeier, T Ghadban, H Stein, M Gomez-Ruiz, J R Izbicki, B Soh Min

Abstract readReview
PubMed Publisher
In one paragraph

Review in Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

D PerezAbteilung für Allgemein‑, Viszeral- und Thoraxchirurgie, Universitätsklinikum Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Deutschland. d.perez@uke.de.
A WoestemeierAbteilung für Allgemein‑, Viszeral- und Thoraxchirurgie, Universitätsklinikum Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Deutschland.
T GhadbanAbteilung für Allgemein‑, Viszeral- und Thoraxchirurgie, Universitätsklinikum Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Deutschland.
H SteinAbteilung für Klinische Entwicklung, Intuitive Surgical, Sunnyvale, CA, USA.
M Gomez-RuizAbteilung für Chirurgie, Universitätshospital Marqués de Valdecilla, Santander, Spanien.
J R IzbickiAbteilung für Allgemein‑, Viszeral- und Thoraxchirurgie, Universitätsklinikum Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Deutschland.
B Soh MinAbteilung für Chirurgie, Medizinische Schule der Yonsei Universität, Seoul, Südkorea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPerforming colorectal surgery with previous da Vinci system generations presented some limitations that caused uncertainty for surgeons as they began to apply robotic technologies. The da Vinci Xi system is designed to overcome these limitations and to enable multiquadrant colorectal surgery.

objectiveThe design concept of the da Vinci Xi system and the standardized access for colorectal surgery are explained. MATERIAL AND

methodsThe da Vinci Xi system applies an overhead boom that maximizes the arm workspace, minimizes interference and makes the port placement universal for standardized access. Colorectal approaches have been validated in numerous cadaver models confirming the reproducibility of the standardized access.

resultsStandardized access with a straight-line port placement is possible in all colorectal applications. For right-sided hemicolectomy, a transverse abdominal approach as well as a suprapubic port placement are possible. Utilizing the same principles, left-sided colectomy, sigmoid colectomy and low anterior resections can be performed. Proctocolectomy is enabled through boom rotation and a second docking. Only minor arm-to-arm interferences occurred and were easily manageable by the bedside assistant. None of the approaches required rearrangement of the patient cart or swapping arms to different port locations.

conclusionThe da Vinci Xi system enables a standardized access for colorectal surgery through a universal straight-line port placement. Learning this standard principle once enables the surgeon to apply it to all colorectal surgeries and shorten the learning curve as well as minimizing stress for both novices and experienced robotic surgeons learning a new surgical robotic platform.

Indexed as

Colorectal SurgeryRobotic Surgical ProceduresCadaverColectomyHumansReproducibility of ResultsMedical deviceMinimally invasive surgeryPort placementRobotic surgeryVisceral surgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.