Evidence map›Paper›PMID 31089203›Full record

ArticleScientific reports2019

Silicon µPCR Chip for Forensic STR Profiling with Hybeacon Probe Melting Curves.

Senne Cornelis, Olivier Tytgat, Maarten Fauvart, Yannick Gansemans, Ann-Sophie Vander Plaetsen, Rodrigo S Wiederkehr, Dieter Deforce, Filip Van Nieuwerburgh, Tim Stakenborg

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. DNA forensics at forty: the way forward.International journal of legal medicine · 2025
    Review
  2. Review
  3. PCR past, present and future.BioTechniques · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Senne CornelisLaboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium.ORCID http://orcid.org/0000-0003-3442-1121
Olivier TytgatLaboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium.ORCID http://orcid.org/0000-0002-1788-5963
Maarten FauvartDepartment of Life Science Technologies, Imec, 3001, Leuven, Belgium.
Yannick GansemansLaboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium.
Ann-Sophie Vander PlaetsenLaboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium.ORCID http://orcid.org/0000-0002-3362-7809
Rodrigo S WiederkehrDepartment of Life Science Technologies, Imec, 3001, Leuven, Belgium.
Dieter DeforceLaboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium. Dieter.Deforce@UGent.be.ORCID http://orcid.org/0000-0002-0635-661X
Filip Van NieuwerburghLaboratory of Pharmaceutical Biotechnology, Ghent University, 9000, Gent, Belgium.ORCID http://orcid.org/0000-0001-8815-5485
Tim StakenborgDepartment of Life Science Technologies, Imec, 3001, Leuven, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.

Indexed as

Lab-On-A-Chip DevicesDNADNA FingerprintingEquipment DesignForensic GeneticsHumansNucleic Acid DenaturationPolymerase Chain ReactionSiliconDNASilicon

Identifiers

PMID31089203
PMCPMC6517373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.