Evidence map›Paper›PMID 31085362›Full record

ArticleActa biomaterialia2019

Nonlinear elasticity of the lung extracellular microenvironment is regulated by macroscale tissue strain.

Ignasi Jorba, Gabriel Beltrán, Bryan Falcones, Béla Suki, Ramon Farré, José Manuel García-Aznar, Daniel Navajas

Open access · greenAbstract read
In one paragraph

Article in Acta biomaterialia, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
6.6field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 67 citations in OpenAlex.

  1. Article
  2. Mechanobiology and Resolution of Lung Fibrosis.Annual review of physiology · 2026
    Review
  3. Review
  4. Integrating mechanical cues inFrontiers in immunology · 2026
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Ignasi JorbaFacultat de Medicina i Ciències de la Salut, Universitat de Barcelona, Barcelona, Spain; Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Barcelona, Spain.
Gabriel BeltránMultiscale in Mechanical and Biological Engineering, Department of Mechanical Engineering, Universidad de Zaragoza, Zaragoza, Spain; Aragón Institute of Engineering Research, Zaragoza, Spain.
Bryan FalconesFacultat de Medicina i Ciències de la Salut, Universitat de Barcelona, Barcelona, Spain.
Béla SukiDepartment of Biomedical Engineering. Boston University, Boston, MA, USA.
Ramon FarréFacultat de Medicina i Ciències de la Salut, Universitat de Barcelona, Barcelona, Spain; Institut d'Investigacions Biomèdiques August Pi Sunyer, Barcelona, Spain; CIBER de Enfermedades Respiratorias, Madrid, Spain.
José Manuel García-AznarMultiscale in Mechanical and Biological Engineering, Department of Mechanical Engineering, Universidad de Zaragoza, Zaragoza, Spain; Aragón Institute of Engineering Research, Zaragoza, Spain.
Daniel NavajasFacultat de Medicina i Ciències de la Salut, Universitat de Barcelona, Barcelona, Spain; Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Barcelona, Spain; CIBER de Enfermedades Respiratorias, Madrid, Spain. Electronic address: dnavajas@ub.edu.
Departament de Salut · ESUniversidad de Zaragoza · ESBoston University · US

Funding

A multi-scale computational model of the extracellular matrix of the lungU01HL139466 · NHLBI · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI SUKI, BELA · 2018 to 2022
$3.9M
NHLBI NIH HHS U01 HL139466
6 · The paper itself

Abstract

The extracellular matrix (ECM) of the lung provides physical support and key mechanical signals to pulmonary cells. Although lung ECM is continuously subjected to different stretch levels, detailed mechanics of the ECM at the scale of the cell is poorly understood. Here, we developed a new polydimethylsiloxane (PDMS) chip to probe nonlinear mechanics of tissue samples with atomic force microscopy (AFM). Using this chip, we performed AFM measurements in decellularized rat lung slices at controlled stretch levels. The AFM revealed highly nonlinear ECM elasticity with the microscale stiffness increasing with tissue strain. To correlate micro- and macroscale ECM mechanics, we also assessed macromechanics of decellularized rat lung strips under uniaxial tensile testing. The lung strips exhibited exponential macromechanical behavior but with stiffness values one order of magnitude lower than at the microscale. To interpret the relationship between micro- and macromechanical properties, we carried out a finite element (FE) analysis which revealed that the stiffness of the alveolar cell microenvironment is regulated by the global strain of the lung scaffold. The FE modeling also indicates that the scale dependence of stiffness is mainly due to the porous architecture of the lung parenchyma. We conclude that changes in tissue strain during breathing result in marked changes in the ECM stiffness sensed by alveolar cells providing tissue-specific mechanical signals to the cells. STATEMENT OF SIGNIFICANCE: The micromechanical properties of the extracellular matrix (ECM) are a major determinant of cell behavior. The ECM is exposed to mechanical stretching in the lung and other organs during physiological function. Therefore, a thorough knowledge of the nonlinear micromechanical properties of the ECM at the length scale that cells probe is required to advance our understanding of cell-matrix interplay. We designed a novel PDMS chip to perform atomic force microscopy measurements of ECM micromechanics on decellularized rat lung slices at different macroscopic strain levels. For the first time, our results reveal that the microscale stiffness of lung ECM markedly increases with macroscopic tissue strain. Therefore, changes in tissue strain during breathing result in variations in ECM stiffness providing tissue-specific mechanical signals to lung cells.

Indexed as

Cellular MicroenvironmentElasticityNonlinear DynamicsAnimalsBiomechanical PhenomenaDimethylpolysiloxanesExtracellular MatrixFinite Element AnalysisLungModels, TheoreticalPorosityRats, Sprague-DawleybaysilonDimethylpolysiloxanesAFMECM micromechanicsMultiscale lung mechanicsTensile testing

Identifiers

PMID31085362
PMCPMC6701712
OpenAlexW2943990749

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.