Evidence map›Paper›PMID 31084829›Full record

ReviewThe Orthopedic clinics of North America2019

Trunnion Corrosion in Total Hip Arthroplasty-Basic Concepts.

Kenneth L Urish, Nicholas John Giori, Jack E Lemons, William M Mihalko, Nadim Hallab

Abstract readReview
In one paragraph

Review in The Orthopedic clinics of North America, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Feasibility of using diamond-like carbon films in total joint replacements: a review.Journal of materials science. Materials in medicine · 2024
    Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. The role of fretting-frequency on the damage modes of THR modular junction: In-vitro study.Materials science & engineering. C, Materials for biological applications · 2021
    Article
  20. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kenneth L UrishArthritis and Arthroplasty Design Group, The Bone and Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center, 300 Halket Street, Suite 1601, Pittsburgh, PA 15213, USA; Department of Orthopaedic Surgery, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA, USA; Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA. Electronic address: urishk2@upmc.edu.
Nicholas John GioriVA Palo Alto Health Care System, Palo Alto, CA, USA; Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA.
Jack E LemonsDepartment of Orthopaedic Surgery, University of Alabama at Birmingham, 1313 13th Street South, Birmingham, AL 35205-5327, USA.
William M MihalkoCampbell Clinic, Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee Health Science Center, 1211 Union Avenue, Suite 510, Memphis, TN 38104, USA.
Nadim HallabDepartment of Orthopaedic Surgery, Rush University, 1653 West Congress Parkway, Chicago, IL 60612, USA.

Funding

Institutional Career Development CoreKL2TR001856 · NCATS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI RAY, KRISTIN N, RUBIO, DORIS M · 2016 to 2025
$13.8M
Biofilm antibiotic tolerance in periprosthetic joint infectionK08AR071494 · NIAMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI URISH, KENNETH L · 2017 to 2021
$831k
NCATS NIH HHS KL2 TR001856NIAMS NIH HHS K08 AR071494
6 · The paper itself

Abstract

There has been increased interest in the role of corrosion in early implant failures and adverse local tissue reaction in total hip arthroplasty. We review the relationship between the different types of corrosion in orthopaedic surgery including uniform, pitting, crevice, and fretting or mechanically assisted crevice corrosion (MACC). Passive layer dynamics serves a critical role in each of these processes. The femoral head-neck trunnion creates an optimal environment for corrosion to occur because of the limited fluid diffusion, acidic environment, and increased bending moment.

Indexed as

Prosthesis DesignProsthesis FailureArthroplasty, Replacement, HipCorrosionHumansMetalsOxidesPostoperative ComplicationsThermodynamicsMetalsOxidesAdverse local tissue reactionCorrosionHead neck taper corrosionPassive layerTotal hip arthroplastyTrunnion

Identifiers

PMID31084829
PMCPMC6521866

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.