SynthesisMedicine2019
Efficacy, safety, and in-hospital outcomes of subcutaneous versus transvenous implantable defibrillator therapy: A meta-analysis and systematic review.
Synthesis in Medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Retrosternal extravascular implantable cardioverter-defibrillators: a systematic review of implant characteristics, defibrillation testing, and acute safety.Future cardiology · 2026Pooled it
- Infection Prevention and Device Pocket Management in Cardiac Implantable Electronic Devices: Emerging Strategies.Current cardiology reports · 2026Review
- The FIB-4 Index Is Independently Associated with QTc Interval in Patients with Ankylosing Spondylitis.Journal of clinical medicine · 2026Article
- Article
- Management of cardiac implantable electronic device infection using a complete interdisciplinary approach.Herzschrittmachertherapie & Elektrophysiologie · 2021Article
- Left-Sided Humerus Fracture as an Unusual Complication of Defibrillation Threshold Testing Following S-ICD Implantation.JACC. Case reports · 2020Article
- Outcomes in Brugada Syndrome Patients With Implantable Cardioverter-Defibrillators: Insights From the SGLT2 Registry.Frontiers in physiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundLead-related complication is an important drawback of trans-venous implantable cardioverter-defibrillators (TV-ICD). The subcutaneous ICD (S-ICD) was developed to overcome ICD lead associated complications; however, whether the S-ICD confers enhanced clinical benefits compared with TV-ICD remains unclear. The present systematic review and meta-analysis aimed to assess TV-ICD and S-ICD for safety, efficacy, and in-hospital outcomes in the prevention of sudden cardiac death (SCD) in patients not requiring pacing.
methodsThe Medline, PubMed, EmBase, and Cochrane Library databases were searched for studies comparing TV-ICD and S-ICD.
resultsA total of 9 eligible studies, including 5 propensity-matched case-control, 3 retrospective, and 1 cross-sectional studies were identified, assessing 7361 patients in all. Pool analyses demonstrated that SICD were associated with lower lead-related complication rates [odds ratio (OR) = 0.13; 95% confidence interval [CI] 0.05-0.33; I = 0%], and S-ICD was more beneficial in terms of reducing ICD shocks [OR = 0.48; 95% CI 0.32-0.72, I = 4%]. In addition, the patients administered S-ICD tend to have shorter length of hospital stay after implantation (SMD = -0.06; 95% CI -0.11 to 0.00, I = 0%) and reduce total complication rates (OR = 0.72; 95% CI 0.50-1.03; I = 18%), non-decreased quality of life (QoL). Moreover, both devices appeared to perform equally well with respect to infection rate and death.
conclusionsAvailable overall data suggested that S-ICD is associated with reducing lead-related complications, ICD shocks. In addition, S-ICD has tendency to shorten hospitalization and reduce total complications, although the difference is no significant. Equivalent death rate, infection, and QoL were found between 2 groups. Therefore, S-ICD could be considered an alternative approach to TV-ICD in appropriate patients for SCD prevention.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials