ArticleJournal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society
Pressure Injury Prevention: Outcomes and Challenges to Use of Resident Monitoring Technology in a Nursing Home.
Article in Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Perceptions of care home residents, families and staff about wearable devices: a scoping review.European geriatric medicine · 2026Article
- Nursing Home Nursing Staff Perspective About Using Subepidermal Moisture Technology for Pressure Injury Prevention.Journal of the American Medical Directors Association · 2026Article
- Stakeholder Perspectives on mHealth Technologies to Prevent Sitting-Acquired Pressure Injuries in Long-Term Care Facilities: Mixed Methods Study.JMIR formative research · 2025Article
- On the Move pad - a portable multipurpose pad: User feedback.The journal of spinal cord medicine · 2025Article
- Wearable devices for patient monitoring in the intensive care unit.Intensive care medicine experimental · 2025Review
- Feasibility and validation of a novel mobility monitoring sensor in hospitalized patients: A prospective cohort study.Journal of clinical and translational science · 2025Article
- Economic Perspective of the Use of Wearables in Health Care: A Systematic Review.Mayo Clinic proceedings. Digital health · 2024Review
- Health Care Workers' Expectations of the Mercury Advance SMARTcare Solution to Prevent Pressure Injuries: Individual and Focus Group Interview Study.JMIR nursing · 2024Article
- Can a prolonged healing pressure injury be benefited by using an AI mattress? A case study.BMC geriatrics · 2024Article
- Influence of Sociodemographic, Organizational, and Social Factors on Turnover Consideration Among Eldercare Workers: A Quantitative Survey.International journal of environmental research and public health · 2023Article
- Development of Smart Clothing to Prevent Pressure Injuries in Bedridden Persons and/or with Severely Impaired Mobility: 4NoPressure Research Protocol.Healthcare (Basel, Switzerland) · 2023Article
- Continuous pressure monitoring of inpatient spinal cord injured patients: implications for pressure ulcer development.Spinal cord · 2023Observational
- Article
- An economic analysis of a wearable patient sensor for preventing hospital-acquired pressure injuries among the acutely ill patients.International journal of health economics and management · 2021Article
- Predicting pressure injury using nursing assessment phenotypes and machine learning methods.Journal of the American Medical Informatics Association : JAMIA · 2021Article
- Application of the educational method of realistic simulation in the treatment of pressure injuries.Revista latino-americana de enfermagem · 2020Article
- Real-time Positioning Among Nursing Home Residents Living With Dementia: A Case Study.Wound management & prevention · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeWe examined the usability, user perceptions, and nursing occupational subculture associated with introduction of a patient monitoring system to facilitate nursing staff implementation of standard care for pressure ulcer/injury prevention in the nursing home setting.
designMixed methods, pre-/posttest design. SUBJECTS AND
settingResident (n = 44) and staff (n = 38) participants were recruited from a 120-bed nursing home in the Southeast United States.
methodsDigital data on frequency and position of residents were transmitted wirelessly from sensors worn on each resident's anterior chest to estimate nursing staff compliance with repositioning standard of care before and after visual monitors were activated to cue staff. The validated Nursing Culture Assessment Tool was used to determine changes in nursing culture. Benefits and challenges of implementation were assessed by 2 focus groups composed of 8 and 5 female members of the nursing staff (RN, LPN, CNA), respectively, and led by the three authors. Descriptive statistics were used for all quantitative variables, and inferential statistics were applied to categorical variables (χ test or Fisher exact test) and continuous variables (analyses of variance or equivalent nonparametric tests), respectively, where a 2-sided P value of <.05 was considered statistically significant.
resultsSystem use significantly (P = .0003) improved compliance with every 2-hour repositioning standards. The nursing culture normative ranking percentage increased from 30.9% to 58.2%; this difference was not statistically significant. Focus groups expressed satisfaction with the monitoring system and recommended improvements to support adaptation and use of technology.
conclusionsStudy findings support the usability of the patient monitoring system to facilitate repositioning. Implementation of multiple strategies for training, supplies, and communication may enhance uptake and effectiveness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials