ArticleActa biomaterialia2019
Zwitterionic poly-carboxybetaine coating reduces artificial lung thrombosis in sheep and rabbits.
Article in Acta biomaterialia, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 75 citations in OpenAlex.
- Zwitterionic Poly(Carboxybetaine Methacrylate)s in Drug Delivery, Antifouling Coatings, and Regenerative Tissue Platforms.Materials (Basel, Switzerland) · 2025Review
- A silicon membrane microfluidic oxygenator for use as an artificial placenta with minimal anticoagulation.Bioengineering & translational medicine · 2025Article
- AG86 Peptide-modified Reactive Oxygen Species-responsive Polymer Nanovesicles for Transdermal Delivery of Hydrophilic Ergothioneine to Basal Keratinocytes.AAPS PharmSciTech · 2025Article
- Five-day Wearable Respiratory Support With a Novel Ambulatory Pulmonary Assist System in an Awake Ovine Model.Transplantation · 2025Article
- Antifouling Zwitterionic Polymer Coatings for Blood-Bearing Medical Devices.Langmuir : the ACS journal of surfaces and colloids · 2025Review
- Progress towards permanent respiratory support.Current opinion in organ transplantation · 2024Review
- Article
- Epoxy silane sulfobetaine block copolymers for simple, aqueous thromboresistant coating on ambulatory assist lung devices.Journal of biomedical materials research. Part A · 2024Article
- Extracorporeal life support without systemic anticoagulation: a nitric oxide-based non-thrombogenic circuit for the artificial placenta in an ovine model.Pediatric research · 2024Article
- Controlled swelling of biomaterial devices for improved antifouling polymer coatings.Scientific reports · 2023Article
- Current knowledge gaps in extracorporeal respiratory support.Intensive care medicine experimental · 2023Review
- Pediatric pulmonary valve replacements: Clinical challenges and emerging technologies.Bioengineering & translational medicine · 2023Review
- Zwitterionic Polysulfobetaine Coating and Antiplatelet Liposomes Reduce Fouling in Artificial Lung Circuits.Macromolecular bioscience · 2023Article
- Nanofibers with homogeneous heparin distribution and protracted release profile for vascular tissue engineering.Frontiers in bioengineering and biotechnology · 2023Article
- Current and Future Engineering Strategies for ECMO Therapy.Advances in experimental medicine and biology · 2023Article
- Polyzwitterionic Coating of Porous Adsorbents for Therapeutic Apheresis.Journal of functional biomaterials · 2022Article
- Bio-inspired hemocompatible surface modifications for biomedical applications.Progress in materials science · 2022Article
- Polycarboxybetaine-Based Hydrogels for the Capture and Release of Circulating Tumor Cells.Gels (Basel, Switzerland) · 2022Article
- A pumpless artificial lung without systemic anticoagulation: The Nitric Oxide Surface Anticoagulation system.Journal of pediatric surgery · 2022Article
- Bioengineering Progress in Lung Assist Devices.Bioengineering (Basel, Switzerland) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
Abstract
Current artificial lungs fail in 1-4 weeks due to surface-induced thrombosis. Biomaterial coatings may be applied to anticoagulate artificial surfaces, but none have shown marked long-term effectiveness. Poly-carboxybetaine (pCB) coatings have shown promising results in reducing protein and platelet-fouling in vitro. However, in vivo hemocompatibility remains to be investigated. Thus, three different pCB-grafting approaches to artificial lung surfaces were first investigated: 1) graft-to approach using 3,4-dihydroxyphenylalanine (DOPA) conjugated with pCB (DOPA-pCB); 2) graft-from approach using the Activators ReGenerated by Electron Transfer method of atom transfer radical polymerization (ARGET-ATRP); and 3) graft-to approach using pCB randomly copolymerized with hydrophobic moieties. One device coated with each of these methods and one uncoated device were attached in parallel within a veno-venous sheep extracorporeal circuit with no continuous anticoagulation (N = 5 circuits). The DOPA-pCB approach showed the least increase in blood flow resistance and the lowest incidence of device failure over 36-hours. Next, we further investigated the impact of tip-to-tip DOPA-pCB coating in a 4-hour rabbit study with veno-venous micro-artificial lung circuit at a higher activated clotting time of 220-300 s (N ≥ 5). Here, DOPA-pCB reduced fibrin formation (p = 0.06) and gross thrombus formation by 59% (p < 0.05). Therefore, DOPA-pCB is a promising material for improving the anticoagulation of artificial lungs. STATEMENT OF SIGNIFICANCE: Chronic lung diseases lead to 168,000 deaths each year in America, but only 2300 lung transplantations happen each year. Hollow fiber membrane oxygenators are clinically used as artificial lungs to provide respiratory support for patients, but their long-term viability is hindered by surface-induced clot formation that leads to premature device failure. Among different coatings investigated for blood-contacting applications, poly-carboxybetaine (pCB) coatings have shown remarkable reduction in protein adsorption in vitro. However, their efficacy in vivo remains unclear. This is the first work that investigates various pCB-coating methods on artificial lung surfaces and their biocompatibility in sheep and rabbit studies. This work highlights the promise of applying pCB coatings on artificial lungs to extend its durability and enable long-term respiratory support for lung disease patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.