Evidence map›Paper›PMID 31081629›Full record

ArticleAnalytical chemistry2019

Drift Subtraction for Fast-Scan Cyclic Voltammetry Using Double-Waveform Partial-Least-Squares Regression.

Carl J Meunier, Gregory S McCarty, Leslie A Sombers

Abstract read
In one paragraph

Article in Analytical chemistry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Waveform Optimization for theACS measurement science au · 2024
    Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Carl J MeunierDepartment of Chemistry , North Carolina State University , Raleigh , North Carolina 27695-8204 , United States.
Gregory S McCartyDepartment of Chemistry , North Carolina State University , Raleigh , North Carolina 27695-8204 , United States.
Leslie A SombersDepartment of Chemistry , North Carolina State University , Raleigh , North Carolina 27695-8204 , United States.ORCID 0000-0002-0978-9795

Funding

Quantitation of Simultaneous Hydrogen Peroxide and Dopamine Dynamics In VivoR01NS076772 · NINDS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI SOMBERS, LESLIE A · 2011 to 2016
$1.5M
NINDS NIH HHS R01 NS076772
6 · The paper itself

Abstract

Background-subtracted fast-scan cyclic voltammetry (FSCV) provides a method for detecting molecular fluctuations with high spatiotemporal resolution in the brain of awake and behaving animals. The rapid scan rates generate large background currents that are subtracted to reveal changes in analyte concentration. Although these background currents are relatively stable, small changes do occur over time. These changes, referred to as electrochemical drift, result in background-subtraction artifacts that constrain the utility of FSCV, particularly when quantifying chemical changes that gradually occur over long measurement times (minutes). The voltammetric features of electrochemical drift are varied and can span the entire potential window, potentially obscuring the signal from any targeted analyte. We present a straightforward method for extending the duration of a single FSCV recording window. First, we have implemented voltammetric waveforms in pairs that consist of a smaller triangular sweep followed by a conventional voltammetric scan. The initial, abbreviated waveform is used to capture drift information that can serve as a predictor for the contribution of electrochemical drift to the subsequent full voltammetric scan using partial-least-squares regression (PLSR). This double-waveform partial-least-squares regression (DW-PLSR) paradigm permits reliable subtraction of the drift component to the voltammetric data. Here, DW-PLSR is used to improve quantification of adenosine, dopamine, and hydrogen peroxide fluctuations occurring >10 min from the initial background position, both in vitro and in vivo. The results demonstrate that DW-PLSR is a powerful tool for evaluating and interpreting both rapid (seconds) and gradual (minutes) chemical changes captured in FSCV recordings over extended durations.

Indexed as

Electrochemical TechniquesLeast-Squares AnalysisAdenosineAnimalsBrainDopamineHydrogen PeroxideMaleRatsRats, Sprague-DawleyAdenosineDopamineHydrogen Peroxide

Identifiers

PMID31081629
PMCPMC7357255

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.