Evidence map›Paper›PMID 31081537›Full record

ArticleEuropean journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology2019

Validation of microbiological testing in cardiovascular tissue establishments: results of a second international quality-round trial.

Sharon Zahra, George Galea, Ramadan Jashari, Pieter Petit, Theo M M H de By

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 4 countries.

Sharon ZahraScottish National Blood Transfusion Service, Edinburgh, UK. szahra@nhs.net.ORCID http://orcid.org/0000-0001-6440-0386
George GaleaNational Blood Transfusion Service, Pietà, Malta.
Ramadan JashariEuropean Homograft Bank St. Jean Clinique, Brussels, Belgium.
Pieter PetitFoundation of European Tissue Banks, Berlin, Germany.
Theo M M H de ByErasmus Medisch Centrum, Rotterdam, The Netherlands.
Clinique Saint Jean · BEErasmus University Rotterdam · NLScottish National Blood Transfusion Service · GBSt. Luke's Hospital · MT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The performance of many laboratories can be evaluated by participation in external quality assessment (EQA) schemes. EQA allows for comparison of a laboratory's performance with a source outside the laboratory-either a peer group of laboratories or a reference laboratory. Such EQA schemes do not exist in tissue banking despite the fact that tissue establishments (TE) perform very complex procedures. This paper describes the first ever EQA scheme in the field specifically assessing microbiological aspects in heart valve (HV) banking. Twenty-two TEs participated. Three HV tissue samples were sent to each participating TE-two contaminated with non-pathogenic micro-organisms and a third negative control. The aims were to isolate and identify the micro-organisms present and then to successfully decontaminate the HV tissue using the routine standard operating procedures of the TE. Eight of the TEs were able to isolate and identify all contaminating micro-organisms present, and of these, five also successfully decontaminated the tissue; 13 TEs failed to establish the identity of one or more of the contaminants; five TEs appear to have introduced contamination during the processing or testing of the tissue; and eight failed to successfully decontaminate the HV tissue. This initiative provides TEs with an international benchmark for tissue product microbiology testing. It has identified significant variation in practice and in the ability of different TEs to identify the presence of contamination. There is now work ongoing with the aim of setting up a regular EQA scheme for HV banking.

Indexed as

Quality ControlBacteriaBenchmarkingClinical Laboratory TechniquesDecontaminationHeart ValvesHumansInternational AgenciesMicrobiological TechniquesTissue BanksTissue TransplantationBankingContaminationHeart valvesMicrobiologyTransplantation

Identifiers

PMID31081537
OpenAlexW2944714902

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.