Evidence map›Paper›PMID 31080341›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2017

Robotic System for MRI-guided Focal Laser Ablation in the Prostate.

Yue Chen, Alexander Squires, Reza Seifabadi, Sheng Xu, Harsh Agrawal, Marcelino Bernardo, Peter Pinto, Peter Choyke, Bradford Wood, Zion Tsz Ho Tse

Open access · greenAbstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 57 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Treatment Planning Strategies for Interstitial Ultrasound Ablation of Prostate Cancer.IEEE open journal of engineering in medicine and biology · 2024
    Article
  6. Open Source MR-Safe Pneumatic Radial Inflow Motor and Encoder (PRIME): Design and Manufacturing Guidelines.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2023
    Article
  7. MR conditional prostate intervention systems and actuations review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Review
  8. Article
  9. Article
  10. MR-Conditional Actuations: A Review.Annals of biomedical engineering · 2020
    Review
  11. Article
  12. MR-conditional steerable needle robot for intracerebral hemorrhage removal.International journal of computer assisted radiology and surgery · 2019
    Article
  13. Article
  14. Article
  15. Characterization and Control of a Pneumatic Motor for MR-conditional Robotic Applications.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Yue ChenCollege of Engineering, The University of Georgia, Athens, GA, 30605, USA.
Alexander SquiresCollege of Engineering, The University of Georgia, Athens, GA, 30605, USA.
Reza SeifabadiCenter for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA.
Sheng XuCenter for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA.
Harsh AgrawalPhilips Research North America, Briarcliff, NY, 10510, USA.
Marcelino BernardoCenter for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA.
Peter PintoCenter for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA.
Peter ChoykeCenter for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA.
Bradford WoodCenter for Interventional Oncology, Department of Radiology and Imaging Sciences, National Institutes of Health, Bethesda, MD, 20892, USA.
Zion Tsz Ho TseCollege of Engineering, The University of Georgia, Athens, GA, 30605, USA.
National Institutes of Health · USUniversity of Georgia · USNational Cancer Institute · USPhilips (United States) · US

Funding

Atlanta Clinical and Translational Science Institute (ACTSI) RenewalUL1TR000454 · NCATS · EMORY UNIVERSITY · PI STEPHENS, DAVID S · 2012 to 2016
$25.8M
Center for Interventional OncologyZIDBC011242 · NCI · DIVISION OF BASIC SCIENCES - NCI · PI WOOD, BRADFORD J · 2009 to 2025
$18.7M
Intramural NIH HHS ZID BC011242NCATS NIH HHS UL1 TR000454
6 · The paper itself

Abstract

MRI-conditional robotic platforms have proved to be an effective approach for image guided interventions. In this study, a computer-assisted, pneumatically-actuated robot was designed, built, and tested for MRI-guided prostate cancer focal laser ablation (FLA). The robotic manipulator provides two active planar degrees of freedom (DoFs) by using a customized CoreXY frame, and one passive rotational DoF. A remote insertion mechanism improves the surgical workflow by keeping the patients inside the scanner during needle insertion. The robotic manipulator was tested in a 3T MR scanner to evaluate its MR compliance, and the results demonstrated that the signal-to-noise ratio (SNR) variation was less than 8%. The in-scanner template positioning accuracy test demonstrated that the manipulator achieves high targeting accuracy with a mean error of 0.46 mm and a standard deviation of 0.25mm. Phantom studies have shown that the needle insertion accuracy of the manipulator is within 2mm (Mean = 1.7mm, StD = 0.2mm).

Indexed as

Focal Laser AblationImage Guided TherapyMRIProstate CancerRobot

Identifiers

PMID31080341
PMCPMC6506217
OpenAlexW2522362134

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.