ArticleBMC ophthalmology2019
Clinical study on combining femtosecond thin- flap and LASIK with the Triple-A profile for high myopia correction.
Article in BMC ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 7 citations in OpenAlex.
- Predictability comparison of central corneal thickness reduction in myopic eyes with or without astigmatism undergoing FS-LASIK with two profiles of MEL 90.Scientific reports · 2026Article
- Efficacy and safety of Bu Jing Yi Shi tables for high myopia: A protocol of systematic review and meta-analysis.Medicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
backgroundFemtosecond laser-assisted LASIK (FS-LASIK) can make ultra-thin corneal flap accurately. MEL 90 excimer laser provides Triple-A ablation mode, which significantly reduces the amount of corneal tissue cutting. This study aimed to investigate the visual and refractive outcomes in patients with high myopia after thin-flap FS-LASIK using the 500 Hz pulse rate of the Triple-A profile.
methodsThis prospective study included 90 eyes from 90 patients received thin-flap FS-LASIK using the 500 Hz pulse rate of the Triple-A profile. According to the pre-operative spherical equivalence (SE), the treated eyes were divided into two groups: the first group (ranged from - 9.0D to - 6.0D) and the second group (ranged from - 11.15D to - 9.0 D). The parameters evaluated pre-operatively and 6 month post-operatively included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), SE, efficacy and safety index, posterior central elevation, and corneal higher-order aberrations (HOAs).
resultsThe efficacy indexes were 1.149 ± 0.150 for the first group and 1.173 ± 0.136 for the second group (P > 0.05), whereas safety indexes were 1.135 ± 0.154 and 1.158 ± 0.137 (P > 0.05) respectively. Moreover, 93.8 and 90.6% of patients had an UDVA of 20/20, 51.2 and 49.8% had a UDVA of 20/16 for the first and second groups, respectively; yet, there were no significant differences between both groups at the 20/20 and the 20/16 levels (P > 0.05). 84 and 100% of the firse group patients had a SE within ±0.5 D and ± 1.0 D, and 82 and 100% of the second group patients. There was no significant myopia regression in both groups after 6 months follow-up. At 1, 3 and 6-month after surgery, there were no significant differences in the posterior central elevation between the two groups (P > 0.05). The induction of total HOAs, spherical aberration, and horizontal coma in the first group were significantly less than that in the second group at the 6- month follow-up (P < 0.05), while the differences of the RMS value of vertical coma between both groups were not significant (P > 0.05). The ablation was significantly associated with the post-operative increase in total HOAs, spherical aberration and horizontal coma (P < 0.05),but not with vertical coma (P > 0.05).
conclusionOur results indicate that using the Triple-A ablation profile of the MEL 90 excimer laser associated with thin-flap is a safe, efficient, and predictable method to correct SE up to - 11.15D. However, for patients with high myopia, under the premise of ensuring a certain optical zone diameter, the ablation depth should be minimized to reduce the increase of the post-operative HOAs so as to improve the visual quality.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.