Evidence map›Paper›PMID 31076839›Full record

ArticleCardiovascular and interventional radiology2019

Accuracy of Length of Virtual Stents in Treatment of Intracranial Wide-Necked Aneurysms.

Kengo Nishimura, Katharina Otani, Ashraf Mohamed, Chihebeddine Dahmani, Toshihiro Ishibashi, Ichiro Yuki, Shogo Kaku, Hiroyuki Takao, Yuichi Murayama

Abstract read
In one paragraph

Article in Cardiovascular and interventional radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kengo NishimuraDivision of Endovascular Neurosurgery, Department of Neurosurgery, School of Medicine, Jikei University, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan. ognek.n@gmail.com.ORCID http://orcid.org/0000-0001-7898-663X
Katharina OtaniSiemens Healthcare K.K., Gate City Osaki West Tower, 1-11-1 Osaki, Shinagawa-ku, Tokyo, 141-8644, Japan.
Ashraf MohamedSiemens Healthcare K.K., Gate City Osaki West Tower, 1-11-1 Osaki, Shinagawa-ku, Tokyo, 141-8644, Japan.
Chihebeddine DahmaniSiemens Healthcare Pte Ltd, Surgery Business Line, 60 MacPherson Road, Singapore, 348615, Singapore.
Toshihiro IshibashiDivision of Endovascular Neurosurgery, Department of Neurosurgery, School of Medicine, Jikei University, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan.
Ichiro YukiDivision of Endovascular Neurosurgery, Department of Neurosurgery, School of Medicine, Jikei University, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan.
Shogo KakuDivision of Endovascular Neurosurgery, Department of Neurosurgery, School of Medicine, Jikei University, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan.
Hiroyuki TakaoDivision of Endovascular Neurosurgery, Department of Neurosurgery, School of Medicine, Jikei University, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan.
Yuichi MurayamaDivision of Endovascular Neurosurgery, Department of Neurosurgery, School of Medicine, Jikei University, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposePrecise stent deployment is important for successful treatment of intracranial aneurysms by stent-assisted coiling (SAC). We evaluated the accuracy of virtual stents generated using commercial stent planning software by comparing the length of virtual and actually deployed intracranial laser cut stents on three-dimensional digital subtraction angiography (3D-DSA) images.

methodsWe retrospectively analyzed the data of 75 consecutive cases of intracranial wide-necked aneurysms treated with the SAC technique using laser cut stents. Based on 3D-DSA images acquired by C-arm CT, stent sizing and placement were intraoperatively simulated by a commercial software application. The difference in length of the stents was estimated by measuring proximal discrepancies between the end points of the virtual and actually deployed stents on fused pre-procedural and post-procedural 3D-DSA images. Discrepancies between distal stent end points were manually minimized. The Kruskal-Wallis test was applied to test whether stent location, type, and length had an effect on difference in length between virtual and real stent.

resultsThe median difference in length between virtual and real stents was 1.58 mm with interquartile range 1.12-2.12 mm. There was no evidence for an effect of stent location (p = 0.23), stent type (p = 0.33), or stent length (p = 0.53) on difference in length between virtual and real stents.

conclusionsStent planning software allows 3D simulation of laser cut stents overlain on 3D-DSA images of vessels and may thus be useful for stent selection and deployment of laser cut stents during stent-assisted coiling of intracranial aneurysms.

Indexed as

Angiography, Digital SubtractionCerebral AngiographyComputed Tomography AngiographyEmbolization, TherapeuticEquipment DesignFemaleHumansImaging, Three-DimensionalIntracranial AneurysmMaleMiddle AgedReproducibility of ResultsRetrospective StudiesStentsTreatment Outcome3D digital subtraction angiographyStent-assisted coilingStent simulation softwareWide-necked aneurysm

Identifiers

PMID31076839
PMCPMC6597734

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.