ReviewBMC surgery2019
The impact of the ultrasonic, bipolar and integrated energy devices in the adrenal gland surgery: literature review and our experience.
Review in BMC surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 29 citations in OpenAlex.
- Advanced bipolar vessel sealing devices vs conventional bipolar energy in minimally invasive hysterectomy: a systematic review and meta-analysis.Archives of gynecology and obstetrics · 2024Pooled it
- A comparison of the Thunderbeat and standard electrocautery devices in head and neck surgery: a prospective randomized controlled trial.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021Trial
- Experimental Investigation into Bipolar Sealability of Elastin-Rich Tissue.Medical sciences (Basel, Switzerland) · 2026Article
- Comparison of the application value of bipolar electrocoagulation and ultrasonic scalpel in robot-assisted thyroid carcinoma surgery: a single-center study based on perioperative indicator and short-term prognosis.Frontiers in surgery · 2026Article
- Giant Adrenal Neuroblastoma in Adults: Surgical Management and Comprehensive Review.Clinical case reports · 2025Article
- Risk factors for postoperative respiratory complications following retroperitoneal laparoscopic adrenalectomy: a cohort study.Gland surgery · 2025Article
- Implementation of a Cost and Variation Reduction Program for Hemostasis Products at a Large Academic Medical Center: A Multi-Stakeholder Perspective.Medical devices (Auckland, N.Z.) · 2025Article
- Outcomes and Follow-Up Trends in Adrenal Leiomyosarcoma: A Comprehensive Literature Review and Case Report.Journal of clinical medicine · 2024Review
- Usefulness of cordless ultrasonic cutting energy devices in endoscopic nipple-sparing mastectomy: a retrospective study.Annals of surgical treatment and research · 2024Article
- Review of Evidence Supporting the Arista™ Absorbable Powder Hemostat.Medical devices (Auckland, N.Z.) · 2024Review
- Impact of Current Technology in Laparoscopic Adrenalectomy: 20 Years of Experience in the Treatment of 254 Consecutive Clinical Cases.Journal of clinical medicine · 2023Review
- A Comparative Study of an Integrated Ultrasonic/Bipolar Sealing Device Versus an Articulating Bipolar Sealing Device for Laparoscopic Liver Surgery.World journal of surgery · 2022Article
- Is There Indication for the Use of Biological Mesh in Cancer Patients?Journal of clinical medicine · 2022Article
- Nondestructive optical feedback systems for use during infrared laser sealing of blood vessels.Lasers in surgery and medicine · 2022Article
- The safety and efficacy of Glubran 2 as biliostatic agent in liver resection.Infectious agents and cancer · 2021Article
- Optical Coherence Tomography Feedback System for Infrared Laser Sealing of Blood Vessels.Proceedings of SPIE--the International Society for Optical EngineeringArticle
- Real-Time, Nondestructive Optical Feedback Systems for Infrared Laser Sealing of Blood Vessels.Proceedings of SPIE--the International Society for Optical EngineeringArticle
- A Real-Time Fluorescence Feedback System for Infrared Laser Sealing of Blood Vessels.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics SocietyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe gold standard approach for surgical treatment of benign and malignant adrenal lesion is considered the laparoscopic one, due to a lot of advantages compared to open approach. The rapid propagation of this surgical technique is due to the diffusion of haemostatic devices in laparoscopic adrenal surgery. The principal aim of this study is to analyze the outcome of LA using each energy modality, evaluating the eventual superiority of an instrument over the others.
methodsA retrospective study, involving 75 consecutive patients submitted to LA by transperitoneal lateral approach from January 2013 to June 2017, was performed. Age less than 70 years old, adrenal adenomas less than 8 cm in diameter, incidentalomas < 6 cm, myelolipomas < 13 cm, adrenal metastases < 7 cm and ASA score ≤ III were the main surgical inclusion criteria. All involved patients were divided into three group, one for each energy device: group 1 - Harmonic Scalpel, group 2 - Ligasure vessel sealing system and group 3 - Thunderbeat. In each group only one device was applied for dissection and haemostasis during the whole operation. Each group consisted of 25 patients, well matched for histology, tumor size and site, gender and age. The following parameters were collected: age, gender, size of the tumor, side of the affected gland, pathology, operating time, intraoperative blood losses, hospitalization time, complication and conversion rate.
resultsThere was no significant statistical difference between groups regarding the relationship between male/female, right site/left site, the mean age, hospitalization time and the tumor size (p > 0.05). Significant statistical difference are detectable in operation time and intraoperative blood losses. Thunderbeat, compared respectively with Ligasure and Harmonic Scalpel, is the fastest device (p < 0,001). The second faster device resulted Harmonic Scalpel, which meanly reduced the operation time compared to Ligasure (p = 0.048). intraoperative blood losses are reduced using Thunderbeat (p < 0,001) and HS (p = 0.006) compared to Ligasure, but between Thunderbeat and Harmonic Scalpel there isn't significant statistical difference (p = 0.178).
conclusionsAnalyzing the results, laparoscopic adrenalectomy carried out using Thunderbeat appeared to show a statistically significant decrease in operation time and intraoperative blood losses compared with laparoscopic adrenalectomy performed using Harmonic Scalpel and Ligasure, while hospitalization time was superimposable in all groups. According to our data, a responsible use of advanced energy devices can improve surgical outcomes guarantying a cost savings and patient's satisfaction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.