ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020

Magnetic resonance imaging can increase the diagnostic accuracy in symptomatic meniscal repair patients.

Emilie Faunø, Ole Gade Sørensen, Torsten Grønbech Nielsen, Martin Lind, Claus Tvedesøe

Open access · bronzeAbstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 8 citations in OpenAlex.

  1. Efficacy of platelet-rich plasma in meniscal repair surgery: a systematic review of randomized controlled trials.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Pooled it
  2. Pooled it
  3. Article
  4. Redefining Failure: Criteria for Unsuccessful Outcomes in Meniscus Repair.Current reviews in musculoskeletal medicine · 2025
    Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Emilie FaunøDepartment of Sports Traumatology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark. emilie@faunoe.dk.ORCID http://orcid.org/0000-0003-0069-5896
Ole Gade SørensenDepartment of Sports Traumatology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
Torsten Grønbech NielsenDepartment of Sports Traumatology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
Martin LindDepartment of Sports Traumatology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
Claus TvedesøeDepartment of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
Aarhus University Hospital · DKAarhus University · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to evaluate meniscal repair healing in symptomatic patients through combined clinical assessment, magnetic resonance imaging (MRI) and re-arthroscopy. This study investigated the diagnostic accuracy of MRI and clinical assessment in determining failed meniscal repair in symptomatic meniscal repair patients, as verified by re-arthroscopy.

methodsEighty patients were included. All had undergone a primary meniscal repair followed by an MRI and re-arthroscopy due to clinical symptoms of a meniscal lesion. A validated semi-quantitative scoring system was employed for identifying MRI-diagnosed healing failure. The clinical assessment was divided into joint swelling, joint-line tenderness, locking and a positive McMurray's test. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of MRI and positive clinical findings were calculated using second-look arthroscopy as a standard.

resultsThe MRI results showed healing of 22 (27.5%) of the menisci and 58 (72.5%) unhealed menisci, whereas second-look arthroscopy identified 15 (19%) healed menisci and 65 (81%) unhealed menisci. The isolated MRI findings were 0.85, 0.8, 0.95 and 0.55 for sensitivity, specificity, PPV and NPV, respectively. The PPVs of the clinical assessments were 0.78, 0.85 and 0.94, with one, two and three clinical findings, respectively. A grade 3 MRI combined with joint-line tenderness presented a PPV of 0.98.

conclusionA supplementary MRI will increase diagnostic accuracy when fewer than three clinical findings are present in a symptomatic meniscal repair patient. The clinical relevance of this finding is that MRI contributes to enhancing the diagnostic accuracy of an unhealed meniscal repair when there are limited clinical signs of meniscal pathology. LEVEL OF EVIDENCE: III.

Indexed as

AdolescentAdultArthroscopyFemaleHumansKnee InjuriesMagnetic Resonance ImagingMaleMenisci, TibialMiddle AgedPhysical ExaminationRetrospective StudiesSecond-Look SurgerySensitivity and SpecificityTibial Meniscus InjuriesYoung AdultClinical assessmentDiagnostic valueMagnetic resonance imagingMeniscal healingMRIRe-arthroscopy

Identifiers

PMID31073840
OpenAlexW2944460263

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked