ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020
Magnetic resonance imaging can increase the diagnostic accuracy in symptomatic meniscal repair patients.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 8 citations in OpenAlex.
- Efficacy of platelet-rich plasma in meniscal repair surgery: a systematic review of randomized controlled trials.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024Pooled it
- Higher healing rate after meniscal repair with concomitant ACL reconstruction for tears located in vascular zone 1 compared to zone 2: a systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Pooled it
- Systematic reviews in PRP-augmented meniscal repair have limited methodological quality: A systematic overview.Journal of experimental orthopaedics · 2026Article
- Redefining Failure: Criteria for Unsuccessful Outcomes in Meniscus Repair.Current reviews in musculoskeletal medicine · 2025Review
- Association Between MRI Signal Intensity of the Repaired Lateral Meniscus and Residual Anterolateral Knee Laxity After ACL Reconstruction.Orthopaedic journal of sports medicine · 2024Article
- Do MRI Results Represent Functional Outcomes Following Arthroscopic Repair of an Isolated Meniscus Tear in Young Patients?-A Prospective Comparative Cohort Study.Clinics and practice · 2024Article
- Failure rate, return-to-sports and magnetic resonance imaging after meniscal repair: 119 patients with 7 years mean follow up.World journal of orthopedics · 2023Article
- Inferior Healing Rate in Isolated Meniscal Repair than that in Meniscal Repair with Concomitant ACL Reconstruction Evaluated with MRI.Malaysian orthopaedic journal · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to evaluate meniscal repair healing in symptomatic patients through combined clinical assessment, magnetic resonance imaging (MRI) and re-arthroscopy. This study investigated the diagnostic accuracy of MRI and clinical assessment in determining failed meniscal repair in symptomatic meniscal repair patients, as verified by re-arthroscopy.
methodsEighty patients were included. All had undergone a primary meniscal repair followed by an MRI and re-arthroscopy due to clinical symptoms of a meniscal lesion. A validated semi-quantitative scoring system was employed for identifying MRI-diagnosed healing failure. The clinical assessment was divided into joint swelling, joint-line tenderness, locking and a positive McMurray's test. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of MRI and positive clinical findings were calculated using second-look arthroscopy as a standard.
resultsThe MRI results showed healing of 22 (27.5%) of the menisci and 58 (72.5%) unhealed menisci, whereas second-look arthroscopy identified 15 (19%) healed menisci and 65 (81%) unhealed menisci. The isolated MRI findings were 0.85, 0.8, 0.95 and 0.55 for sensitivity, specificity, PPV and NPV, respectively. The PPVs of the clinical assessments were 0.78, 0.85 and 0.94, with one, two and three clinical findings, respectively. A grade 3 MRI combined with joint-line tenderness presented a PPV of 0.98.
conclusionA supplementary MRI will increase diagnostic accuracy when fewer than three clinical findings are present in a symptomatic meniscal repair patient. The clinical relevance of this finding is that MRI contributes to enhancing the diagnostic accuracy of an unhealed meniscal repair when there are limited clinical signs of meniscal pathology. LEVEL OF EVIDENCE: III.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials