ArticleAnalytica chimica acta2019
Isolation and identification of Listeria monocytogenes utilizing DC insulator-based dielectrophoresis.
Article in Analytica chimica acta, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Quantifying and Minimizing the Variance of Gradient Insulator-Based Dielectrophoresis.Micromachines · 2026Article
- An Overview of Microfluidic Phenotype Separation of Bacteria.Current pharmaceutical design · 2026Review
- A fast and label-free DC-iDEP microfluidic device detects bacterial motility and andrographolide efficacy in motility inhibition.Mikrochimica acta · 2025Article
- Recent Advances in Dielectrophoretic Manipulation and Separation of Microparticles and Biological Cells.Biosensors · 2024Review
- Article
- Development of a DC-Biased AC-Stimulated Microfluidic Device for the Electrokinetic Separation of Bacterial and Yeast Cells.Biosensors · 2024Article
- Assessing the Discriminatory Capabilities of iEK Devices under DC and DC-Biased AC Stimulation Potentials.Micromachines · 2023Article
- Recent advances and challenges in temperature monitoring and control in microfluidic devices.Electrophoresis · 2023Review
- Microfluidic Systems for Blood and Blood Cell Characterization.Biosensors · 2022Review
- The latest advances on nonlinear insulator-based electrokinetic microsystems under direct current and low-frequency alternating current fields: a review.Analytical and bioanalytical chemistry · 2022Review
- Particle trapping in electrically driven insulator-based microfluidics: Dielectrophoresis and induced-charge electrokinetics.Electrophoresis · 2021Review
- Dielectrophoresis: Developments and applications from 2010 to 2020.Electrophoresis · 2021Review
- Comparison between Whatman FTA Elute Cards and Conventional Swab for the Detection of Pathogenic Enteric Bacteria Using an RT-qPCR Assay.The Canadian journal of infectious diseases & medical microbiology = Journal canadien des maladies infectieuses et de la microbiologie medicale · 2021Article
- Determination of the Empirical Electrokinetic Equilibrium Condition of Microorganisms in Microfluidic Devices.Biosensors · 2020Article
- Quantifying Heterogeneity According to Deformation of the U937 Monocytes and U937-Differentiated Macrophages Using 3D Carbon Dielectrophoresis in Microfluidics.Micromachines · 2020Article
- Electrophysiology-based stratification of pancreatic tumorigenicity by label-free single-cell impedance cytometry.Analytica chimica acta · 2020Article
- Differential Biophysical Behaviors of Closely Related Strains of Salmonella.Frontiers in microbiology · 2020Article
- Effects of surface treatments on trapping with DC insulator-based dielectrophoresis.The Analyst · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Foodborne pathogens pose one of the greatest challenges facing public health in the modern day. One important pathogen, Listeria monocytogenes, is known to be challenging to detect and identify. Three serovars cause most of the Listeria related food-borne illnesses, which the Centers for Disease Control currently utilizes a combination of pulsed-field gel electrophoresis and whole genome sequencing for identification and the determination of clusters and outbreaks. There is a potential method for rapid collection of epidemiological information by exploiting the electrokinetic and dielectrophoretic properties of the L. monocytogenes serovars. Using dielectrophoresis, the three most commonly identified serovars of L. monocytogenes can be distinguished from each other. The electrokinetic and dielectrophoretic mobilities of each serovar was determined through a combination of electrokinetic velocity and dielectrophoretic trapping assessments, in conjunction with finite element multi-physics modeling. A mathematical model of the data, which defines the various factors of dielectrophoretic trapping, is utilized and verified based on the behavior of L. monocytogenes in the microchannel. The trapping condition for the serovars were evaluated as 2.8±0.2×10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.