ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020
Uniplane medial opening wedge high tibial osteotomy relative to a biplane osteotomy can reduce the incidence of lateral-hinge fracture.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 17 citations in OpenAlex.
- Reduced lateral hinge stress and fracture risk in double-hinge medial open-wedge high tibial osteotomy: A finite element study.Joint diseases and related surgery · 2026Article
- Fixation stability and stress redistribution following metal block use in opening-wedge high tibial osteotomy: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- Article
- Biomechanical evaluation of a newly designed locking plate for opening wedge high tibial osteotomy: stress distribution and stability in the presence of lateral hinge fracture.Journal of orthopaedic surgery and research · 2024Article
- Required force for distraction during medial opening wedge high tibial osteotomy may serve as a predictive indicator for lateral hinge fracture.Journal of experimental orthopaedics · 2024Article
- Lateral hinge fracture in medial opening wedge high tibial osteotomy: a narrative review.EFORT open reviews · 2023Review
- Modified treatment of knee osteoarthritis complicated with femoral varus deformity: A case report.World journal of clinical cases · 2022Article
- Incidence and Factors Affecting the Occurrence of Lateral Hinge Fracture After Medial Opening-Wedge High Tibial Osteotomy.Orthopaedic journal of sports medicine · 2021Article
- Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures.Journal of orthopaedic surgery and research · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeWith surgical modifications reflecting plate design differences of the specific rigid locking plate adding a metal wedge, uniplane high tibial osteotomy (HTO) has fewer lateral-hinge fractures and fewer plate irritations than biplane HTO.
methodsUniplane HTO with a rigid locking plate adding a metal wedge was compared with biplane HTO with a rigid locking plate including a proximal D-hole. For comparison, the HTO patients' medical records and radiological results in a single institution were retrospectively reviewed. The Oxford knee score 2 years post-operation, CT scan at post-operative day 2 and serial standing long-bone scanography were reviewed to evaluate clinical outcome and radiological results, including the incidence of lateral-hinge fracture, plate irritation and correction loss to varus alignment.
resultsA total of 103 knees, including 59 uniplane HTO and 44 biplane HTO, were enrolled. The Oxford scores were 38.1 ± 7.8 in the uniplane group and 35.9 ± 8.3 in the biplane group (ns). On CT scans, more lateral-hinge fractures developed in the biplane group, and seven knees (12%) of the uniplane group and 12 knees (27%) of the biplane group had Takeuchi type I stable hinge fracture (p < 0.05); unstable fracture was not noted in either group. Plate irritation occurred in nine knees (19%) of the uniplane group and in 14 knees (32%) of the biplane group, and the difference was statistically significant (p < 0.05).
conclusionIn clinical situations including the use of surgical modifications reflecting plate design differences, fewer lateral-hinge fractures developed after uniplane medial opening-wedge HTO compared with biplane HTO. Uniplane HTO potentially represents a better option than biplane HTO for the prevention of lateral-hinge fracture. LEVEL OF EVIDENCE: IV.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.