Evidence map›Paper›PMID 31062936›Full record

Trial reportInternational journal of laboratory hematology2019

Establishing a reference range for thromboelastograph parameters in the neonatal period.

Qin Liu, Chunfen Xu, Xin Chen, Jia Wang, Zhunhui Ke, Hongbing Hu

Open access · hybridAbstract readClinical Trial
In one paragraph

Trial report in International journal of laboratory hematology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. TEGDiagnostics (Basel, Switzerland) · 2021
    Review
  11. Review
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Qin LiuDepartment of Blood Transfusion, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.ORCID https://orcid.org/0000-0003-3316-7985
Chunfen XuDepartment of Blood Transfusion, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Xin ChenDepartment of Blood Transfusion, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Jia WangDepartment of Blood Transfusion, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Zhunhui KeDepartment of Blood Transfusion, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Hongbing HuDepartment of Blood Transfusion, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Wuhan Children's Hospital · CN

Funding

Science and Technology Project of Zhejiang Province Grant No. 2018C37008Wuhan Scientific Research Projects Grant No. WX15C22
6 · The paper itself

Abstract

introductionAcquired coagulation disorders are a common cause of neonatal bleeding. The thromboelastograph (TEG) comprehensively assesses haemostatic processes in the body. Unfortunately, the reference range of TEG parameters in the neonatal period has not yet been evaluated, which limits the use of the TEG in neonates. In this study, we aimed to establish the reference range of TEG parameters for the neonatal period.

methodsThis study included 371 full-term infants (≥37 weeks of gestation), and we divided these infants into three groups according to age as follows: 1, 2-7 and 8-28 days. We measured their peripheral blood using TEG, coagulation routine and platelet count tests. We analysed differences among the groups.

resultsThe reference ranges for TEG parameters are presented as medians and reference ranges (2.5th and 97.5th percentiles) as follows: R (clot reaction time, seconds) 4.80 (2.80-7.17), Angle (fibrin production rate) 69.90 (44.91-78.89), K (clot kinetics, min) 1.40 (0.80-4.50), MA (maximum amplitude, mm) 63.50(44.34-74.66) and LY30 (lysis at 30 minutes, %) 0.10 (0.10-6.95). There were significant differences in Angle, K, MA and LY30 values between the different neonatal day age groups.

conclusionThis study preliminarily establishes a reference range for TEG parameters during the neonatal period. The age of a newborn had a large influence on TEG parameters. Additionally, we demonstrated a correlation between laboratory tests and TEG parameters for this age period. The reference values provided herein are meaningful for future studies.

Indexed as

HemostasisBlood Coagulation DisordersFemaleHumansInfant, NewbornMalePlatelet CountReference ValuesRetrospective StudiesThrombelastographyneonatal periodneonatereference rangethromboelastograph

Identifiers

PMID31062936
PMCPMC6850129
OpenAlexW2944413970

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.