Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position.
Trial report in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 16 citations in OpenAlex.
- Effect of individualized positive end-expiratory pressure titration guided by electrical impedance tomography on oxygenation in patients undergoing laparoscopic surgery in the lateral decubitus position: a randomized controlled study.Korean journal of anesthesiology · 2026Trial
- Intraoperative titration of positive end-expiratory pressure in urological patients undergoing laparoscopic procedures under lateral position: a randomized controlled trial.BMC anesthesiology · 2025Trial
- Impact of Manual Sustained Inflation vs Stepwise PEEP on Pulmonary and Cerebral Outcomes in Carotid Endarterectomy Patients.Medical science monitor : international medical journal of experimental and clinical research · 2024Trial
- Effect of driving pressure on early postoperative lung gas distribution in supratentorial craniotomy: a randomized controlled trial.BMC anesthesiology · 2023Trial
- Lung electrical impedance tomography during positioning, weaning and chest physiotherapy in mechanically ventilated critically ill patients: a narrative review.Annals of intensive care · 2025Review
- Individualized PEEP without Recruitment Maneuvers Improves Intraoperative Oxygenation: A Randomized Controlled Study.Bioengineering (Basel, Switzerland) · 2023Article
- Lung regions identified with CT improve the value of global inhomogeneity index measured with electrical impedance tomography.Quantitative imaging in medicine and surgery · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To determine the effect of various PEEP levels on electrical impedance tomography (EIT) measured differences in regional ventilation, hemodynamics, lung mechanics and parameters of alveolar gas exchange. Thirty three patients scheduled for elective urologic surgery in general anesthesia in lateral decubitus position were randomized into three groups-PEEP 0, 5 and 10 mbar. EIT recording, arterial blood gas analysis and hemodynamic parameters were captured at three timepoints-before induction (T0), 5 min after lateral positioning (T1) and 90 min after positioning (T2). Dynamic compliance (Cdyn) was measured at T1 and T2. Offline EIT data analysis was performed to calculate EIT derived parameters of ventilation distribution. Patients ventilated with PEEP of 10 mbar had a significantly lower A-a (alveolo arterial) gradient over measurements and symmetrical distribution of ventilation measured by EIT. There was no significant difference in Cdyn, center of ventilation indices and inhomogeneity index between groups. There was no difference of mean arterial pressure, cardiac index and heart rate between groups. Patients with 5 mbar of PEEP had higher stroke volume index compared to 0 and 10 mbar at baseline and over measurements. Nondependent/dependent TV ratio as well as global inhomogeneity index were correlated with A-a gradient. Dynamic compliance showed no correlation to A-a gradient. In our study, a PEEP level of 10 mbar improved alveolar gas exchange without compromising hemodynamic stability in patients mechanically ventilated in the lateral decubitus position. EIT measured parameters may be used to determine optimal ventilation parameters in these patients with inhomogeneous lung mechanics. Further studies are needed in patients with various lung pathologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.