Evidence map›Paper›PMID 31060312›Full record

ArticleSensors (Basel, Switzerland)2019

A Novel Traveling-Wave-Based Method Improved by Unsupervised Learning for Fault Location of Power Cables via Sheath Current Monitoring.

Mingzhen Li, Jianming Liu, Tao Zhu, Wenjun Zhou, Chengke Zhou

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mingzhen LiSchool of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China. barryjrlee@whu.edu.cn.
Jianming LiuSchool of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China. ljming@263.net.
Tao ZhuState Grid Hubei Electric Power Company, State Grid Corporation of China, No. 1701 Jiefang Avenue, Jiang'an District, Wuhan 430013, China. zt1231036@yeah.net.
Wenjun ZhouSchool of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China. wjzhou@whu.edu.cn.
Chengke ZhouSchool of Electrical Engineering and Automation, Wuhan University, No. 299, Bayi Road, Wuchang District, Wuhan 430072, China. C.Zhou@gcu.ac.uk.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to improve the practice in maintenance of power cables, this paper proposes a novel traveling-wave-based fault location method improved by unsupervised learning. The improvement mainly lies in the identification of the arrival time of the traveling wave. The proposed approach consists of four steps: (1) The traveling wave associated with the sheath currents of the cables are grouped in a matrix; (2) the use of dimensionality reduction by t-SNE (t-distributed Stochastic Neighbor Embedding) to reconstruct the matrix features in a low dimension; (3) application of the DBSCAN (density-based spatial clustering of applications with noise) clustering to cluster the sample points by the closeness of the sample distribution; (4) the arrival time of the traveling wave can be identified by searching for the maximum slope point of the non-noise cluster with the fewest samples. Simulations and calculations have been carried out for both HV (high voltage) and MV (medium voltage) cables. Results indicate that the arrival time of the traveling wave can be identified for both HV cables and MV cables with/without noise, and the method is suitable with few random time errors of the recorded data. A lab-based experiment was carried out to validate the proposed method and helped to prove the effectiveness of the clustering and the fault location.

Indexed as

circuit faultsfault currentsfault locationpower cablessheath currents

Identifiers

PMID31060312
PMCPMC6539397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.