Evidence map›Paper›PMID 31058818›Full record

ArticleSensors (Basel, Switzerland)2019

Robust Smartphone Assisted Biosensing Based on Asymmetric Nanofluidic Grating Interferometry.

Foelke Purr, Max-Frederik Eckardt, Jonas Kieserling, Paul-Luis Gronwald, Thomas P Burg, Andreas Dietzel

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Foelke PurrInstitute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany. f.purr@tu-braunschweig.de.ORCID 0000-0002-0094-7486
Max-Frederik EckardtInstitute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany. max.frederik.eckardt@gmail.com.
Jonas KieserlingInstitute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany. j.kieserling@tu-braunschweig.de.
Paul-Luis GronwaldInstitute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany. paul-luis.gronwald@tu-braunschweig.de.
Thomas P BurgMax-Planck Institute for Biophysical Chemistry, 37077 Göttingen, Germany. tburg@mpibpc.mpg.de.
Andreas DietzelInstitute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany. a.dietzel@tu-braunschweig.de.ORCID 0000-0003-2090-6259

Funding

Bundesministerium für Wirtschaft und Energie KF3259501MD3 / KF3085602MD3
6 · The paper itself

Abstract

Point-of-care systems enable fast therapy decisions on site without the need of any healthcare infrastructure. In addition to the sensitive detection, stable measurement by inexperienced persons outside of laboratory facilities is indispensable. A particular challenge in field applications is to reduce interference from environmental factors, such as temperature, to acceptable levels without sacrificing simplicity. Here, we present a smartphone-based point-of-care sensor. The method uses an optofluidic grating composed of alternating detection and reference channels arranged as a reflective phase grating. Biomolecules adsorbing to the detection channel alter the optical path length, while the parallel reference channels enable a direct common mode rejection within a single measurement. The optical setup is integrated in a compact design of a mobile readout device and the usability is ensured by a smartphone application. Our results show that different ambient temperatures do not have any influence on the signal. In a proof-of concept experiment we measured the accumulation of specific molecules in functionalized detection channels in real-time and without the need of any labeling. Therefore, the channel walls have been modified with biotin as capture molecules and the specific binding of streptavidin was detected. A mobile, reliable and robust point-of-care device has been realized by combining an inherently differential measurement concept with a smartphone-based, mobile readout device.

Indexed as

biosensingcommon mode rejectioninterferometrynanofluidicoptofluidic gratingportable point-of-care (POC)smartphone-based

Identifiers

PMID31058818
PMCPMC6540137

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.