Evidence map›Paper›PMID 31057923›Full record

ArticleMicrosystems & nanoengineering2018

Towards smart self-clearing glaucoma drainage device.

Hyunsu Park, Amir Hossein Raffiee, Simon W M John, Arezoo M Ardekani, Hyowon Lee

Open access · goldAbstract read
In one paragraph

Article in Microsystems & nanoengineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Hyunsu Park1Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Devices, Purdue University, West Lafayette, IN 47907 USA.
Amir Hossein Raffiee2School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907 USA.
Simon W M John3Howard Hughes Medical Institute, The Jackson Laboratory, Bar Harbor, ME 04609 USA.
Arezoo M Ardekani2School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907 USA.
Hyowon Lee1Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Devices, Purdue University, West Lafayette, IN 47907 USA.
Purdue University West Lafayette · USJackson Laboratory · US

Funding

Indiana Clinical and Translational Sciences InstituteUL1TR001108 · NCATS · INDIANA UNIVERSITY INDIANAPOLIS · PI DENNE, SCOTT C., SHEKHAR, ANANTHA · 2013 to 2017
$23.3M
In vivo evaluation of implantable self-clearing catheter for hydrocephalusR21NS095287 · NINDS · PURDUE UNIVERSITY · PI LEE, HYOWON · 2016 to 2017
$409k
NCATS NIH HHS UL1 TR001108NINDS NIH HHS R21 NS095287
6 · The paper itself

Abstract

For patients who are unresponsive to pharmacological treatments of glaucoma, an implantable glaucoma drainage devices (GDD) are often used to manage the intraocular pressure. However, the microscale channel that removes excess aqueous humor from the anterior chamber often gets obstructed due to biofouling, which necessitates additional surgical intervention. Here we demonstrate the proof-of-concept for smart self-clearing GDD by integrating magnetic microactuators inside the drainage tube of GDD. The magnetic microactuators can be controlled using externally applied magnetic fields to mechanically clear biofouling-based obstruction, thereby eliminating the need for surgical intervention. In this work, our prototype magnetic microactuators were fabricated using low-cost maskless photolithography to expedite design iteration. The fabricated devices were evaluated for their static and dynamic mechanical responses. Using transient numerical analysis, the fluid-structure interaction of our microactuator inside a microtube was characterized to better understand the amount of shear force generated by the device motion. Finally, the anti-biofouling performance of our device was evaluated using fluorescein isothiocyanate labeled bovine serum albumin. The microactuators were effective in removing proteinaceous film deposited on device surface as well as on the inner surface of the microchannel, which supports our hypothesis that a smart self-clearing GDD may be possible by integrating microfabricated magnetic actuators in chronically implanted microtubes.

Identifiers

PMID31057923
PMCPMC6220179
OpenAlexW2898665365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.