Evidence map›Paper›PMID 31055691›Full record

ArticleBiomechanics and modeling in mechanobiology2019

Microfluidic and computational study of structural properties and resistance to flow of blood clots under arterial shear.

Alexander Y Mitrophanov, Vijay Govindarajan, Shu Zhu, Ruizhi Li, Yichen Lu, Scott L Diamond, Jaques Reifman

Open access · hybridAbstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Thrombosis and Hemodynamics: external and intrathrombus gradients.Current opinion in biomedical engineering · 2021
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Alexander Y MitrophanovThe Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, 20817, USA. alex@bhsai.org.ORCID http://orcid.org/0000-0002-9019-4034
Vijay GovindarajanThe Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, 20817, USA.
Shu ZhuInstitute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Ruizhi LiInstitute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Yichen LuInstitute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Scott L DiamondInstitute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA, 19104, USA.
Jaques ReifmanDepartment of Defense Biotechnology High Performance Computing Software Applications Institute, Telemedicine and Advanced Technology Research Center, U.S. Army Medical Research and Materiel Command, Fort Detrick, MD, 21702-5012, USA. jaques.reifman.civ@mail.mil.ORCID http://orcid.org/0000-0001-7292-2029
University of Pennsylvania · USHenry M. Jackson Foundation · USTelemedicine & Advanced Technology Research Center · US

Funding

Multiscale Analysis of TraumaU01HL131053 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI DIAMOND, SCOTT L · 2016 to 2020
$3.8M
Blood Systems BiologyR33HL087317 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI DIAMOND, SCOTT L · 2006 to 2008
$937k
NHLBI NIH HHS R33 HL087317NHLBI NIH HHS U01 HL131053
6 · The paper itself

Abstract

The ability of a blood clot to modulate blood flow is determined by the clot's resistance, which depends on its structural features. For a flow with arterial shear, we investigated the characteristic patterns relating to clot shape, size, and composition on the one hand, and its viscous resistance, intraclot axial flow velocity, and shear distributions on the other. We used microfluidic technology to measure the kinetics of platelet, thrombin, and fibrin accumulation at a thrombogenic surface coated with collagen and tissue factor (TF), the key clot-formation trigger. We subsequently utilized the obtained data to perform additional calibration and validation of a detailed computational fluid dynamics model of spatial clot growth under flow. We then ran model simulations to gain insights into the resistance of clots formed under our experimental conditions. We found that increased thrombogenic surface length and TF surface density enhanced the bulk thrombin and fibrin generation in a nonadditive, synergistic way. The height of the platelet deposition domain-and, therefore, clot occlusivity-was rather robust to thrombogenic surface length and TF density variations, but consistently increased with time. Clot viscous resistance was non-uniform and tended to be higher in the fibrin-rich, inner "core" region of the clot. Interestingly, despite intraclot structure and viscous resistance variations, intraclot flow velocity variations were minor compared to the abrupt decrease in flow velocity around the platelet deposition region. Our results shed new light on the connection between the structure of clots under arterial shear and spatiotemporal variations in their resistance to flow.

Indexed as

Computer SimulationMicrofluidicsModels, CardiovascularVascular ResistanceArteriesBlood Flow VelocityCalibrationFibrinFluorescenceHumansHydrodynamicsKineticsThrombinThromboplastinThrombosisFibrinThrombinThromboplastinAxial flow velocityBlood flowFibrinPlateletsThrombinViscous resistance

Identifiers

PMID31055691
PMCPMC6748893
OpenAlexW2943846229

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.