Validity of transit time-based blood pressure measurements in patients with and without heart failure or pulmonary arterial hypertension across different breathing maneuvers.

Sara Becker, Jens Spiesshoefer, Tobias Brix, Izabela Tuleta, Michael Mohr, Michele Emdin, Matthias Boentert, Alberto Giannoni

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Sleep & breathing = Schlaf & Atmung, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Sara BeckerRespiratory Physiology Laboratory, Department of Neurology with Institute for Translational Neurology, University of Muenster, Muenster, Germany.
Jens SpiesshoeferRespiratory Physiology Laboratory, Department of Neurology with Institute for Translational Neurology, University of Muenster, Muenster, Germany. jens.spiesshoefer@ukmuenster.de.ORCID http://orcid.org/0000-0001-8205-1749
Tobias BrixInstitute of Medical Informatics, University of Muenster, Muenster, Germany.
Izabela TuletaDepartment of Cardiology I, University Hospital Muenster, Muenster, Germany.
Michael MohrDepartment of Medicine A, Hematology, Oncology and Pulmonary Medicine, University Hospital Muenster, Muenster, Germany.
Michele EmdinCardiovascular Medicine Division, Fondazione Toscana Gabriele Monasterio, National Research Council, CNR-Regione Toscana, Scuola Superiore San't Anna, Pisa, Italy.
Matthias BoentertRespiratory Physiology Laboratory, Department of Neurology with Institute for Translational Neurology, University of Muenster, Muenster, Germany.
Alberto GiannoniCardiovascular Medicine Division, Fondazione Toscana Gabriele Monasterio, National Research Council, CNR-Regione Toscana, Scuola Superiore San't Anna, Pisa, Italy.
Scuola Superiore Sant'Anna · ITUniversity Hospital Münster · DEAugenstern · DEUniversity of Münster · DE

Funding

Else Kröner-Fresenius-Stiftung A_109
6 · The paper itself

Abstract

purposePulse transit time (PTT) derived by ECG and plethysmographic signal can be a promising alternative to invasive or oscillometry-based blood pressure (BP) monitoring in sleep laboratories because it does not cause arousals from sleep. Therefore, this study assessed the validity of PTT for BP monitoring under sleep laboratory-like conditions.

methodsTen volunteers (55.8 ± 19.6 years), 12 patients with heart failure with reduced ejection fraction (HFrEF; 67.3 ± 8.6 years), and 14 patients with Nizza class I pulmonary arterial hypertension (PAH; 59.5 ± 13.4 years) performed different breathing patterns to simulate nocturnal sleep-disordered breathing (SDB). BP was measured at least every 15 min over 1 h using oscillometry (Task Force Monitor™) and PTT (SOMNOscreen™) devices in free breathing conditions and during SDB simulation (alternating phases of hyperventilation and apneas).

resultsOne hundred forty-two points of measurements were collected. No difference was found in both mean systolic BP (SBP) and diastolic BP (DBP) between oscillometric PTT-based BP measurements in the whole population and throughout the whole recording (SBP 111.3 ± 15.1 mmHg versus 110.0 ± 14.7 mmHg, p = 0.051; DBP 69.9 ± 12.2 versus 69.9 ± 14.2 mmHg, p = 0.701). Likewise, no significant difference in SBP and DBP was found between the two methods in the subgroups of healthy subjects, HFrEF patients and PAH patients, both in free breathing conditions (p > 0.05) and during SDB simulation (p > 0.05).

conclusionsWhen monitoring BP in healthy subjects, and in patients with HFrEF or PAH, PTT provides a BP estimation comparable with oscillometric measurement, though slightly inaccurate, both in the condition of regular and unstable breathing.

Indexed as

AdultAgedArousalBlood PressureCardiac Output, LowElectrocardiographyFemaleHeart FailureHumansHypertension, PulmonaryMaleMiddle AgedOscillometryPlethysmographyPolysomnographyPulse Wave AnalysisBlood pressure monitoringHeart failurePulse transit timeSleep-disordered breathing

Identifiers

PMID31049851
OpenAlexW2943240741

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.