ArticlePediatric radiology2019
Pediatric optic nerve and optic nerve sheath diameter on magnetic resonance imaging.
Article in Pediatric radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Orbital Doppler Ultrasonography and Optic Nerve Sheath Diameter in Pediatric Brain Death Evaluation.Journal of clinical medicine · 2026Article
- The diagnostic value of MRI findings in pediatric idiopathic intracranial hypertension: a case-control study.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2024Article
- Magnetic Resonance-Based Assessment of Optic Nerve Sheath Diameter: A Prospective Observational Cohort Study on Inter- and Intra-Rater Agreement.Journal of clinical medicine · 2023Article
- Dilated Optic Nerve Sheath in Mucopolysaccharidosis I: Common and Not Necessarily High Intracranial Pressure.AJNR. American journal of neuroradiology · 2023Article
- Pediatric reference values of anterior visual pathway structures measured with axis-correction on high-resolution 3D T2 fast spin echo sequences.BMC pediatrics · 2022Article
- Causes of poor eye contact in infants: a population-based study.BMC ophthalmology · 2021Article
- Determination of ventriculoperitoneal shunt dysfunction using optic nerve sheath diameter measurement on CT scan in pediatric patients with hydrocephalus.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2021Article
- Assessment of the visual pathways in patients with neurofibromatosis-1 by 3S-space technique with 3-Tesla MRITurkish journal of medical sciences · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe normal values of optic nerve diameter and optic nerve sheath diameter might be beneficial in defining an abnormality such as optic nerve hypoplasia, or enlarged subarachnoid space, reflecting the state of increased intracranial pressure.
objectiveTo study the normal optic nerve diameter and optic nerve sheath diameter on magnetic resonance imaging (MRI) in the early years of postnatal visual development from MRI of the brain. MATERIALS AND
methodsMRI of the brain in patients ages 4 years and younger were gathered. Forty-two studies with normal intracranial findings and a lack of history of increased intracranial pressure were retrospectively reviewed by two reviewers using axial T2-weighted images. Measurements were performed in transverse diameter perpendicular to the optic nerve at 3 mm behind the globe.
resultsThe mean optic nerve diameter of the 77 optic nerves were 2.5 mm (95% confidence interval [CI] 2.4-2.6). The mean optic nerve sheath diameter values of the 79 optic nerve sheath complexes were 5.0 mm (95% CI 4.9-5.1). The mean±standard deviation optic nerve diameter and optic nerve sheath diameter stratified by each age groups were, respectively, 0 to <1 year: 2.3±0.40 and 4.81±0.37; 1 to <2 years: 2.6±0.2 and 5.0±0.4; 2 to <3 years: 2.4±0.3 and 4.9±0.6, and 3 to <4 years: 2.9±0.4 and 5.2±0.60 mm.
conclusionSeventy-four of the 77 measurements (96%) were of the measurements were above the threshold of 2 mm for optic nerve diameter. Seventy-seven of the 79 measurements (97%) were of the measurements were below the threshold of 6 mm for optic nerve sheath diameter.
Indexed as
Identifiers
31049608What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.