Evidence map›Paper›PMID 31046513›Full record

ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2019

Tissue-mimicking thermochromic phantom for characterization of HIFU devices and applications.

Avinash Eranki, Andrew S Mikhail, Ayele H Negussie, Prateek S Katti, Bradford J Wood, Ari Partanen

Abstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. MR relaxation times of agar-based tissue-mimicking phantoms.Journal of applied clinical medical physics · 2022
    Article
  10. Article
  11. Article
  12. Review
  13. High-Intensity Focused Ultrasound (HIFU) Triggers Immune Sensitization of Refractory Murine Neuroblastoma to Checkpoint Inhibitor Therapy.Clinical cancer research : an official journal of the American Association for Cancer Research · 2020
    Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Avinash Erankia Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.
Andrew S Mikhaila Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.ORCID 0000-0001-9206-5765
Ayele H Negussiea Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.ORCID 0000-0003-3340-3351
Prateek S Kattia Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.
Bradford J Wooda Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.
Ari Partanena Center for Interventional Oncology, Radiology and Imaging Sciences , Clinical Center and National Cancer Institute, National Institutes of Health , Bethesda , MD , USA.ORCID 0000-0003-1985-149X

Funding

Center for Interventional OncologyZIDBC011242 · NCI · DIVISION OF BASIC SCIENCES - NCI · PI WOOD, BRADFORD J · 2009 to 2025
$18.7M
MEDICAL SCIENTIST TRAINING PROGRAMT32GM008719 · NIGMS · UNIV OF NORTH CAROLINA CHAPEL HILL · PI DARVILLE, TONI, DESHMUKH, MOHANISH P · 1999 to 2023
$15.1M
Interventional OncologyZIACL040015 · CLC · CLINICAL CENTER · PI WOOD, BRADFORD · 2009 to 2025
$0k
Intramural NIH HHS ZIA CL040015Intramural NIH HHS ZID BC011242NIGMS NIH HHS T32 GM008719
6 · The paper itself

Abstract

purposeTissue-mimicking phantoms (TMPs) are synthetic materials designed to replicate properties of biological tissues. There is a need to quantify temperature changes following ultrasound or magnetic resonance imaging-guided high intensity focused ultrasound (MR-HIFU). This work describes development, characterization and evaluation of tissue-mimicking thermochromic phantom (TMTCP) for direct visualization and quantification of HIFU heating. The objectives were to (1) develop an MR-imageable, HIFU-compatible TMTCP that reports absolute temperatures, (2) characterize TMTCP physical properties and (3) examine TMTCP color change after HIFU. METHODS AND MATERIALS: A TMTCP was prepared to contain thermochromic ink, silicon dioxide and bovine serum albumin (BSA) and its properties were quantified. A clinical MRI-guided and a preclinical US-guided HIFU system were used to perform sonications in TMTCP. MRI thermometry was performed during HIFU, followed by T2-weighted MRI post-HIFU. Locations of color and signal intensity change were compared to the sonication plan and to MRI temperature maps.

resultsTMTCP properties were comparable to those in human soft tissues. Upon heating, the TMTCP exhibited an incremental but permanent color change for temperatures between 45 and 70 °C. For HIFU sonications the TMTCP revealed spatially sharp regions of color change at the target locations, correlating with MRI thermometry and hypointense regions on T2-weighted MRI. TMTCP-based assessment of various HIFU applications was also demonstrated.

conclusionsWe developed a novel MR-imageable and HIFU-compatible TMTCP to characterize HIFU heating without MRI or thermocouples. The HIFU-optimized TMTCP reports absolute temperatures and ablation zone geometry with high spatial resolution. Consequently, the TMTCP can be used to evaluate HIFU heating and may provide an in vitro tool for peak temperature assessment, and reduce preclinical in vivo requirements for clinical translation.

Indexed as

High-Intensity Focused Ultrasound AblationHumansMagnetic Resonance ImagingThermometryHIFUhyperthermiaMRIthermochromicTissue-mimicking phantom

Identifiers

PMID31046513
PMCPMC6625350

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.