Evidence map›Paper›PMID 31037865›Full record

ArticleAnnals of laboratory medicine2019

Performance of the cobas u 701 Analyzer in Urinary Tract Infection Screening.

Victoria Ortiz de la Tabla, Gregoria Gázquez, Ana Infante, Coral Martin, Fernando Buñuel, Félix Gutiérrez

Open access · diamondAbstract readEvaluation Study
In one paragraph

Article in Annals of laboratory medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Victoria Ortiz de la TablaMicrobiology Service, Hospital Universitario de San Juan, Alicante, Spain. ortiz_vic@gva.es.ORCID https://orcid.org/0000-0002-6932-4236
Gregoria GázquezMicrobiology Service, Hospital Universitario de San Juan, Alicante, Spain.ORCID https://orcid.org/0000-0003-2189-8924
Ana InfanteMicrobiology Service, Hospital Universitario de San Juan, Alicante, Spain.ORCID https://orcid.org/0000-0001-6526-1728
Coral MartinMicrobiology Service, Hospital Universitario de San Juan, Alicante, Spain.ORCID https://orcid.org/0000-0003-1156-9203
Fernando BuñuelMicrobiology Service, Hospital Universitario de San Juan, Alicante, Spain.ORCID https://orcid.org/0000-0001-6603-5693
Félix GutiérrezInfectious Diseases Unit, Hospital General Universitario de Elche, Alicante, Spain.ORCID https://orcid.org/0000-0002-9485-6867
Hospital Universitari Sant Joan D'Alacant · ESUniversitat de Miguel Hernández d'Elx · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNegative urine cultures to rule out urinary tract infections (UTI) generate a considerable laboratory workload; thus, a rapid screening test is desirable. We evaluated the performance of a new automated microscopy analyzer, cobas u 701 (Roche Diagnostics International, Rotkreuz, Switzerland) for the screening of UTI, and developed a rule-out strategy to reduce the number of samples requiring culture. We also assessed squamous epithelial cell (SEC) count as a predictor of culture contamination.

methodsIn total, 1,604 urine samples from outpatients were analyzed with cobas u 701 and culture. Bacterial (BAC) and white blood cell (WBC) counts were used for sample interpretation. To determine a useful cut-off point to predict negative cultures, we selected the highest sensitivity and specificity values obtained from ROC curves. Diagnostic accuracy by age and gender was evaluated.

resultsUrine culture showed growth of ≥10⁴ colony forming units (CFU)/mL in 256 samples (16.0%). The highest sensitivity (91.8%) and specificity (68.4%) were obtained for cut-off points of 119 BAC/μL and 22 WBC/μL. The combination of BAC and WBC improved the performance of the rule-out strategy with a low rate of false-negative results (1.5%) and a high negative predictive value (NPV, 97.3%). Fifty-seven percent of the samples would not have required culture. SEC count was a poor predictor of culture contamination.

conclusionscobas u 701 can substantially reduce the number of urine samples requiring culture, with a low false-negative rate and a high NPV.

Indexed as

AdolescentAdultArea Under CurveAutomationBacteriaDiagnostic ErrorsFemaleHumansLeukocyte CountMaleMicroscopyMiddle AgedProspective StudiesROC CurveSensitivity and SpecificityUrinary Tract InfectionsAutomated microscopy analyzercobas u 701Screening urine samplesUrinary tract infectionUrine culture

Identifiers

PMID31037865
PMCPMC6502947
OpenAlexW2943493372

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked