Evidence map›Paper›PMID 31035602›Full record

ArticleJournal of clinical medicine2019

Incidental Finding of Strut Malapposition Is a Predictor of Late and Very Late Thrombosis in Coronary Bioresorbable Scaffolds.

Niklas F Boeder, Melissa Weissner, Florian Blachutzik, Helen Ullrich, Remzi Anadol, Monique Tröbs, Thomas Münzel, Christian W Hamm, Jouke Dijkstra, Stephan Achenbach and 2 more

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. The Impact of Underlying Plaque Characteristics Following the Third-Generation Resorbable Magnesium Scaffold Implantation: An Intravascular OCT Assessment up to 12-Months.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025
    Article
  2. Article
  3. Observational
  4. [Structural design and biomechanical numerical analysis of body-fitted stent in stenotic vessels].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Niklas F BoederMedical Clinic I, University Hospital of Giessen, Klinikstrasse 33, 35392 Giessen, Germany. niklas.boeder@innere.med.uni-giessen.de.
Melissa WeissnerZentrum für Kardiologie, University Hospital Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany and German Center for Cardiac and Vascular Research (DZHK), Standort Rhein-Main. melissaweissner@web.de.
Florian BlachutzikMedical Clinic I, University Hospital of Giessen, Klinikstrasse 33, 35392 Giessen, Germany. Florian.Blachutzik@innere.med.uni-giessen.de.
Helen UllrichZentrum für Kardiologie, University Hospital Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany and German Center for Cardiac and Vascular Research (DZHK), Standort Rhein-Main. hullrich@students.uni-mainz.de.
Remzi AnadolZentrum für Kardiologie, University Hospital Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany and German Center for Cardiac and Vascular Research (DZHK), Standort Rhein-Main. remzi.anadol@unimedizin-mainz.de.
Monique TröbsDepartment of Cardiology, University Hospital of Erlangen, Ulmenweg 18, 91054 Erlangen, Germany. monique.troebs@uk-erlangen.de.
Thomas MünzelZentrum für Kardiologie, University Hospital Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany and German Center for Cardiac and Vascular Research (DZHK), Standort Rhein-Main. tmuenzel@uni-mainz.de.ORCID 0000-0001-5503-4150
Christian W HammMedical Clinic I, University Hospital of Giessen, Klinikstrasse 33, 35392 Giessen, Germany. christian.hamm@innere.med.uni-giessen.de.
Jouke DijkstraDepartment of Radiology, Leiden University Medical Center, P.O. Box 9600 (mailstop C2-S), 2300 Leiden, The Netherlands. j.dijkstra@lumc.nl.ORCID 0000-0002-8666-3731
Stephan AchenbachDepartment of Cardiology, University Hospital of Erlangen, Ulmenweg 18, 91054 Erlangen, Germany. stephan.achenbach@uk-erlangen.de.
Holger M NefMedical Clinic I, University Hospital of Giessen, Klinikstrasse 33, 35392 Giessen, Germany. holger.nef@innere.med.uni-giessen.de.
Tommaso GoriZentrum für Kardiologie, University Hospital Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany and German Center for Cardiac and Vascular Research (DZHK), Standort Rhein-Main. tommaso.gori@unimedizin-mainz.de.ORCID 0000-0003-2917-6707

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Malapposition is a common finding in stent and scaffold thrombosis (ScT). Evidence from studies with prospective follow-up, however, is scarce. We hypothesized that incidental observations of strut malapposition might be predictive of late ScT during subsequent follow-up. One hundred ninety-seven patients were enrolled in a multicentre registry with prospective follow-up. Optical coherence tomography (OCT), performed in an elective setting, was available in all at 353 (0-376) days after bioresorbable scaffold (BRS) implantation. Forty-four patients showed evidence of malapposition that was deemed not worthy of intervention. Malapposition was not associated with any clinical or procedural parameter except for a higher implantation pressure (

Indexed as

bioresorbable scaffoldoptical coherence tomographystent thrombosis

Identifiers

PMID31035602
PMCPMC6571797

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.