Evidence map›Paper›PMID 31031564›Full record

ArticleElectrochemistry communications2017

Towards a minimally invasive device for beta-lactam monitoring in humans.

Timothy Miles Rawson, Sanjiv Sharma, Pantelis Georgiou, Alison Holmes, Anthony Cass, Danny O'Hare

Open access · greenAbstract read
In one paragraph

Article in Electrochemistry communications, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 48 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Closed-loop control of continuous piperacillin delivery: AnFrontiers in bioengineering and biotechnology · 2022
    Article
  6. Review
  7. Review
  8. Review
  9. Aptamer-Based Detection of Ampicillin in Urine Samples.Antibiotics (Basel, Switzerland) · 2020
    Article
  10. Review
  11. Review
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Timothy Miles RawsonNational Institute for Health Research Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance, Imperial College London, Hammersmith Campus, Du Cane Road, London. W12 0NN. United Kingdom.
Sanjiv SharmaDepartment of Chemistry & Institute of Biomedical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom.
Pantelis GeorgiouDepartment of Electrical and Electronic Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, United Kingdom.
Alison HolmesNational Institute for Health Research Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance, Imperial College London, Hammersmith Campus, Du Cane Road, London. W12 0NN. United Kingdom.
Anthony CassDepartment of Chemistry & Institute of Biomedical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom.
Danny O'HareDepartment of Bioengineering, Imperial College London, London, SW7 2AZ, United Kingdom.
Imperial College London · GBNIHR Imperial Biomedical Research Centre · GBImperial College Healthcare NHS Trust · GBNational Institute for Health Research · GB

Funding

Department of Health II-LA-0214-20008
6 · The paper itself

Abstract

Antimicrobial resistance is a leading patient safety issue. There is a need to develop novel mechanisms for monitoring and subsequently improving the precision of how we use antibiotics. A surface modified microneedle array was developed for monitoring beta-lactam antibiotic levels in human interstitial fluid. The sensor was fabricated by anodically electrodepositing iridium oxide (AEIROF) onto a platinum surface on the microneedle followed by fixation of beta-lactamase enzyme within a hydrogel. Calibration of the sensor was performed to penicillin-G in buffer solution (PBS) and artificial interstitial fluid (ISF). Further calibration of a platinum disc electrode was undertaken using amoxicillin and ceftriaxone. Open-circuit potentials were performed and data analysed using the Hill equation and log(concentration [M]) plots. The microneedle sensor demonstrated high reproducibility between penicillin-G runs in PBS with mean K

Indexed as

antibiotic resistanceBeta-lactam antibiotic monitoringcontinuous monitoringminimally invasive

Identifiers

PMID31031564
PMCPMC6485621
OpenAlexW2734361299

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.