Evidence map›Paper›PMID 31028693›Full record

ArticleJournal of biomedical optics2019

All-reflective ring illumination system for photoacoustic tomography.

Suhail Salem Alshahrani, Yan Yan, Naser Alijabbari, Alexander Pattyn, Ivan Avrutsky, Eugene Malyarenko, Joemini Poudel, Mark Anastasio, Mohammad Mehrmohammadi

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. High-speed multiview imaging approaching 4pi steradians using conic section mirrors: theoretical and practical considerations.Journal of the Optical Society of America. A, Optics, image science, and vision · 2021
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Suhail Salem AlshahraniWayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States.
Yan YanWayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States.
Naser AlijabbariWayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States.
Alexander PattynWayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States.
Ivan AvrutskyWayne State University, Department of Electrical and Computer Engineering, Detroit, Michigan, United States.
Eugene MalyarenkoBarbara Ann Karmanos Cancer Institute, Detroit, Michigan, United States.
Joemini PoudelWashington University in St. Louis, Biomedical Engineering Department, St. Louis, Washington, United States.
Mark AnastasioWashington University in St. Louis, Biomedical Engineering Department, St. Louis, Washington, United States.
Mohammad MehrmohammadiWayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States.
Wayne State University · USMichigan United · USWashington University in St. Louis · USWayne State College · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Given that breast cancer is the second leading cause of cancer-related deaths among women in the United States, it is necessary to continue improving the sensitivity and specificity of breast imaging systems that diagnose breast lesions. Photoacoustic (PA) imaging can provide functional information during in vivo studies and can augment the structural information provided by ultrasound (US) imaging. A full-ring, all-reflective, illumination system for photoacoustic tomography (PAT) coupled to a full-ring US receiver is developed and tested. The US/PA tomography system utilizes a cone mirror and conical reflectors to optimize light delivery for PAT imaging and has the potential to image objects that are placed within the ring US transducer. The conical reflector used in this system distributes the laser energy over a circular cross-sectional area, thereby reducing the overall fluence. This, in turn, allows the operator to increase the laser energy achieving better cross-sectional penetration depth. A proof-of-concept design utilizing a single cone mirror and a parabolic reflector is used for imaging cylindrical phantoms with light-absorbing objects. For the given phantoms, it has been shown that there was no restriction in imaging a given targeted cross-sectional area irrespective of vertical depth, demonstrating the potential of mirror-based, ring-illuminated PAT system. In addition, the all-reflective ring illumination method shows a uniform PA signal across the scanned cross-sectional area.

Indexed as

Photoacoustic TechniquesTomographyUltrasonography, MammaryEquipment DesignPhantoms, ImagingTransducersconical mirrorfull-ring illuminationomnidirectionalphotoacoustic tomographyring ultrasound transducerultrasound tomography

Identifiers

PMID31028693
PMCPMC6906953
OpenAlexW2996462472

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.