Evidence map›Paper›PMID 31028206›Full record

ArticleIn vivo (Athens, Greece)

Three-dimensional Assessment of the Breast: Validation of a Novel, Simple and Inexpensive Scanning Process.

Carlo M Oranges, Srinivas Madduri, Philipp Brantner, Bilal Msallem, Salvatore Giordano, Benito Benitez, Daniel F Kalbermatten, Dirk J Schaefer, Florian M Thieringer

Abstract read
In one paragraph

Article in In vivo (Athens, Greece). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Carlo M OrangesDepartment of Plastic, Reconstructive, Aesthetic, and Hand Surgery, Basel University Hospital, University of Basel, Basel, Switzerland carlo.oranges@usb.ch florian.thieringer@usb.ch.
Srinivas MadduriDepartment of Plastic, Reconstructive, Aesthetic, and Hand Surgery, Basel University Hospital, University of Basel, Basel, Switzerland.
Philipp BrantnerMedical Additive Manufacturing Research Group, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Bilal MsallemMedical Additive Manufacturing Research Group, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Salvatore GiordanoDepartment of Plastic and General Surgery, Turku University Hospital, University of Turku, Turku, Finland.
Benito BenitezMedical Additive Manufacturing Research Group, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Daniel F KalbermattenDepartment of Plastic, Reconstructive, Aesthetic, and Hand Surgery, Basel University Hospital, University of Basel, Basel, Switzerland.
Dirk J SchaeferDepartment of Plastic, Reconstructive, Aesthetic, and Hand Surgery, Basel University Hospital, University of Basel, Basel, Switzerland.
Florian M ThieringerMedical Additive Manufacturing Research Group, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland carlo.oranges@usb.ch florian.thieringer@usb.ch.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimMethods to assess three-dimensionally the breast surface are increasingly used in plastic and reconstructive surgery. The aim of this study was to validate the use of the Structure Sensor 3D scanner (Occipital, Inc., Boulder, CO, USA) connected to an iPad Pro (Apple, Inc., Cupertino, CA, USA) as a novel, inexpensive and handheld three-dimensional scanning process. MATERIALS AND

methodsSurface images of a medical human female anatomy torso model of rigid plastic were repeatedly acquired with Structure Sensor 3D scanner and compared with those obtained using two clinically established 3D imaging systems. Digital measurements of vector and surface breast distances were analyzed using Mimics® Innovation Suite 20 medical imaging software (Materialise, Leuven, Belgium).

resultsThe analysis of variance (ANOVA) revealed no statistically significant difference among measurements obtained using different scanning processes for all the variables examined (p>0.05).

conclusionThe study demonstrates analogous practicability and reliability for surface image acquisition using the newly introduced Structure Sensor 3D scanner and other clinically established scanners.

Indexed as

Diagnostic ImagingImaging, Three-DimensionalAnalysis of VarianceBreastFemaleHumansReproducibility of ResultsTomography, X-Ray Computed3D scanningphotogrammetrysurface imagingthree-dimensionalvirtual surgical planning

Identifiers

PMID31028206
PMCPMC6559897

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.